Stack Venting
Wet Venting
Misc Venting
Prohibited Venting
100

The place where a vent stack must connect at the base of a drainage stack

What is below the lowest fixture?

100

The minimum size diameter for a wet vent

What is 2"?

100

A type of vent in which a waste branch acts as a vent for a fixture on the same floor level

What is wet venting?

100

A fitting that acts as a one way valve to allow air in for venting without allowing air to escape(against code in Massachusetts)

What is a Provent?

200

The place where a vent stack must connect at the top of a drainage stack

What is 6" above the FLR of the highest fixture being served?

200

The point to which a wye must be rolled up for a wet vent

What is breaking the centerline?

200

A vertical pipe in a building that does not receive any drainage and allows air to circulate within the DWV system.

What is a vent stack?

200

When a fitting providing a vent is too close to the trap it serves

what is crown venting?

300

The amount of stories before a relief vent is required for a vent stack

What is 10 stories?

300

In a bathroom group with a 2-inch horizontal waste, this fixture's 2-inch drain extension is permitted to serve as the wet vent for the bathroom fixtures

What is a Lavatory?

300

The height a vent must extend above the roof when the roof is used as a parking garage or observation deck.

what is 8 feet?

300

The minimum distance a trap has to be from the fitting that is providing a vent

what is 2 pipe diameters?

400

When stack venting fixtures at the highest branch interval of a 3-inch stack, horizontal waste pipes must not exceed this pitch per foot

What is 1/4 inch pitch per foot?

400

Name two of the five specific fixtures or appliances explicitly prohibited by code from having their waste or vent piping serve as a wet vent

What are Kitchen Sinks, Garbage Disposals, Dishwashers, Washing Machines, or Culinary Fixtures? 

400

This specific type of vent is permitted when an individual vent for a sink or lavatory cannot rise 6 inches above the flood level rim before turning horizontal

What is a bow vent?

400

The point below which a vent may not connect to a waste branch

What is the trap arm?

500

The minimum allowable diameter in inches for a main stack vent or vent stack serving a building drain in any structure

What is 3 inches?

500

Two lavatories installed adjacent to each other within 6 feet of a main stack may be installed on a horizontal waste branch without an independent vent if the branch is at least this size throughout

What is 2 inches?

500

An engineered system with specialized fittings that allow fixtures to be vented without following the traditional plumbing code

What is Sovent?

500

Combination waste and vent systems are prohibited without Special-Permission and are strictly limited to these two specific plumbing fixtures

What are floor drains and sinks?