Point-of-Use Care
Clean, Disinfect, Sterlize
Steam Sterilization
Low-Temp Sterilization
PPE & Quality Assurance
100

POU treatment starts immediately after this.

What is: instrument use.

100

This step must happen before disinfection or sterilization.

What is: cleaning. 

100

The gold standard for sterilization.

What is: steam sterilization.

100

Low-temperature sterilization operates below approximately this temperature.

What is: 60°C. 

100

PPE item required specifically when a splash risk exists.

What is a: face shield. 

200

The golden rule of POU care.

What is: Never allow to dry before cleaning. 

200

Disinfection eliminates most pathogens but does NOT destroy these.

What are: bacterial spores. 

200

The typical temperature for a gravity steam sterilization cycle.

What is: 250°F. 

200

These types of devices require low-temperature sterilization.

What are: heat- and moisture-sensitive devices.

200

The three types of sterilizer monitoring.

What are: mechanical, chemical, and biological. 

300

Type of instrument that must be flushed at point-of-use.

What is a: lumened instrument. 

300

The process that destroys ALL microorganisms, including spores.

What is: sterilization. 

300

The four critical factors steam sterilization depends on.

What are: steam quality, temperature, pressure, and exposure time. 

300

Two common low-temperature sterilization technologies.

What are: VHP and EtO (ethylene oxide). 

300

An organization whose sterile processing guidelines must be followed.

What is: AAMI (or AORN, CDC, or WHO). 

400

POU care prevents blood and debris from forming this, which impairs cleaning.

What is: biofilm. 

400

The number of microorganisms on a contaminated object; also called bioload.

What is: bioburden. 

400

Sterilizers that use repeated steam flushes and pressure pulses to remove air.

What are: steam flush-pressure pulse (SFPP) sterilizers. 

400

Low-temperature method used primarily for immersible devices.

What is: peracetic acid.

400

These must be followed alongside manufacturer instructions.

What are: the most current organizational policies. 

500

Required type of container for transporting contaminated instruments.

What is a: closed, labeled container. 

500

When sterilization is complete, instruments are safe for these procedures.

What are: invasive procedures.

500

The key difference between terminal sterilization and flash sterilization.

What is: terminal = packaged; flash = unpackaged. 

500

A challenge specific to EtO sterilization not shared by steam.

What are: longer cycle times and required aeration. 

500

Quality assurance measure that supports traceability of sterilized items.

What is: documentation. 