Circuit Venting
HWT and Storage
Flush Valves
Res. Fixtures
Com. Fixtures
100

True or False : The final fixture on a circuit vent must be a water closet.

what is False

100

What kind of alteration can be made to a T&P valve

what is none

100

what is used to signify the flush volumes of various diaphragms and piston assemblies 

what is colour code

100

what is the minimum size of a floor drain

what is 2" 

2.4.9.3 NPCC

100

how many vent pipes should oil interceptors be provided with

 what is 2

200

A sanitary drainage pipe is permitted to serve as an additional circuit vent provided it is sized as a _____

What is a Wet Vent

2.5.3.1 (7)

200

The discharge pipe from a T&P valve must terminate with an air break, not more than

What is 12"

2.6.1.7 (5)

200

what size supply line is common for a metering type flush valve for a urinal

what is 1/2 "

200

Discharge pipes serving a macerating toilet shall not be less then ____ NPS

What is 3/4"

NPCC 2.4.9.2 (4)

200

what is the maximum length of a F.O.P for a commercial kitchen sink

what is 1200 mm

2.4.8.2

300

Fixtures with fixture outlet pipes less than NPS 2 shall be.

NPCC-2.5.3.1 

What is separately vented or separately circuit vented

300

If a gas water heater is installed in this location it must be in a pan to prevent damage.

what is a ceiling or roof space or over a floor of wood construction

2.6.1.7 (9)

300

except for a metering valve, flush valves have a minimum operating pressure of _____ and a max of ______

what is 15 psi and 80 psi

300

The bathtub waste and overflow connections can be

A.) Both direct and indirect

B.) indirect

C.)Direct

ILM

What is A.) Both direct and indirect

300

what are the 3 installation types of grease interceptors 

what is floor mounted, recessed and semi-recessed

400

A stack is permitted to be connected upstream of a circuit vented fixture 

What is False/No

2.5.1.3 (1)

400

the pressure relief valve of a HWT should be located so that the pressure in the tank does not exceed what Kpa (or psi) any under condition of flow within the distribution system.

what is 35 Kpa or 5 psi 

2.6.1.7 (1)

400

what size is the outlet tube on a water closet

what is 1 1/2 "

400

For cleanouts less than 3" what is the maximum spacing between One Way- Rodding cleanouts

What is 7.5 Meters

NPCC 2.4.7.2

400

in buildings of other than residential occupancy, shut off valves shall be provided on the water supply to what

every fixture, or

any group of fixtures in the same room, not including a water closet (separate)

500

Where are additional circuit vents required?

What is where changes of direction accumulatively exceed 45 Degrees or where more then 8 circuit vented fixtures are connected to a branch between vent pipe connections.

500

What is the equation for finding the boiling temperature of water in F with a closed vessel?

What is 

(sqrt Pressure x 14) + 198 F

500

what table is used in the NPCC for sizing a water distribution supply line for a water closet with a direct flush valve

what is table 2.6.3.2 (A)

500

Hydraulic load of a Potato Peeler

What is 3 FU

NPCC 2.4.9.3

500

What is the minimum Temperature of a commercial Dishwasher

What is 180 F (82.2 C)