__________ requires a 24" minimum.
Maryland
Identify each part?
1) Regulator 2) Regulator Vent 3) Riser Valve (Stopcock) 4) Meter Nut (Swivel Nut)
Report any SOS to ____________ or your ___________?
Dispatch or your Supervisor
Vent terminations shall allow gas to vent freely away from _______, _______, __________ or _________?
Building openings, windows, doors or Air Intakes.
from an IRV regulator with an inlet connection larger than 3/4" maintain ________ clearance.
3'
4' is the?
Maximum distance between protection posts.
Service lines in private property _______ inches.
12
Identify each component?
1) Bypass valves 2) Control lines 3) Meter Instrument 4) Meter
A Structure Over Service is an?
An Enclosed Dwelling, intended for occupancy, built over an existing service line.
All vent terminations shall be a Minimum _________ inches above grade with an _________ resistant screen.
12inches, Insect
From an IRV regulator with 3/4" inlet connection maintain ____ clearance.
2'
Guards may consist of __________, ________, ______, etc?
Posts, Bollards, Railings
18" for distribution lines in ___________ or ___________?
Streets or Roads
Unusual meter sounds may indicate?
The meter is operating abnormally.
What is Not an SOS _____, _______, _______, ________, _________________?
Car port, Shed, Porches, Decks & Services & risers originally installed through foundation (older homes with indoor meters)
All Vent lines shall terminate ___________________?
Outdoors.
Inside meters maintain a minimum of _____ away from sources of ignition or heat that will raise the temperature of the meter above ____F?
3 Feet 120 Degrees Fahrenheit.
Refer services not meeting a minimum depth to ___________ ____________?
Corporate Engineering.
Rapid meter dial movement may indicate that the ___ is flowing rapidly or a major ____________ is downstream of the meter?
Gas, Major Leak
Additions, Attached / Detached garages & Workshops are known as an?
SOS...
Riser valve that is 75% closed requires?
Immediate Action.
Outside meters maintain a minimum of ______ away from arc producing equipment or other sources of ignition.
1'
If there is No Immediate Hazard. What should you do?
Schedule it for repairs.
Meters and piping exposed to traffic must be _____________?
Protected.
Pipes connected to valves shall be?
Plugged.