SMOKE BARRIERS
HAZARDOUS AREA PROTECTION
LIFE SAFETY
Saturday Night LIVE! Fire Safety
LIFE SAFETY
GENERAL
100

IN A NEW HEALTH CARE FACILITY WHAT IS THE REQUIRED RATING FOR A SMOKE BARRIER WALL?

1 HOUR (LS 101 Chapter 18.3.7.3)

100

WHAT DOES THE RED H ON THE LIFE SAFETY PLANS MEAN?

HAZARDOUS ROOM

100

THE RING OR CUP THAT GOES AROUND THE SPRINKLER HEAD IS CALLED WHAT AND CAN YOU SPELL IT?

ESCUTCHEON PLATE

100

This “G” shaped letter comes between “F” and H.”

What is letter "G"

100

PULL STATIONS ARE REQUIRED TO BE WITHIN HOW MANY FEET OF A REQUIRED EXIT?

5 FEET

100

WHAT IS THE MAXIMUM DEAD-END CORRIDOR LIMIT IN A HEALTHCARE FACILITY?

30 FT, (LS 101 Chapter 18.2.5.2)

200

ARE DOORS IN A SMOKE BARRIER IN A NEW HEALTHCARE FACILITY REQUIRED TO LATCH? SELF-CLOSE?

NOT REQUIRED TO LATCH, BUT ARE REQUIRED TO SELF OR AUTOMATICALLY CLOSE. (LS 101 Chapter 18.3.7.8)

200

WHAT IS THE MAXIMUM ALLOWABLE DISTANCE BETWEEN FIRE EXTINGUISHERS?

150 FT

200

I MUST BE ABLE TO REACH A FIRE EXTINGUISHER WITHIN HOW MANY FEET?

75 FT IN ANY DIRECTION

200

WHAT TYPE OF FIRE EXTINGUISHER IS LOCATED INSIDE THE KITCHEN AREA MARKED WITH LETTER "K" AND IS USED TO PUT OUT GREASE FIRES?

"K" - Class/Type

200

WHAT DISTANCE MUST I KEEP CLEAR IN FRONT OF MED GAS ZONE VALVES AND ELECTRICAL PANELS?

36 INCHES

200

WHAT IS LOCATED IN ABOVE THE CEILING WITHIN THE HVAC SYSTEM, PENETRATING A FIRE WALL THAT SHUTS AND SEALS OFF YOUR SMOKE COMPARTMENT?

FIRE DAMPER

300

WHAT IS THE MAXIMUM TRAVEL DISTANCE FROM ANY POINT IN A SMOKE COMPARTMENT TO REACH A SMOKE BARRIER DOOR IN A NEW OR EXISTING HEALTHCARE FACILITY?

200 FT (LS 101 Chapter 18.3.7.1(4))

300

HOW MANY FULL O2 CYLINDERS ARE ALLOWED WITHIN A SINGLE SMOKE COMPARTMENT?

12

300

WHAT IS THE DISTANCE I MUST MAINTAIN A STORAGE FREE SPACE BELOW A SPRINKLER HEAD DEFLECTOR?

18 INCHES

300

This number comes between 5 and 7.

What is number "6"

300

NAME THESE FIVE RESPONSIBILITIES FOR FIRE WARDENS IN THE EVENT OF A FIRE EMERGENCY.

1. PUT ON YOUR VEST 2. HORIZONTALLY EVACUATE TO THE NEXT ADJACENT SMOKE COMPARTMENT 3. GO RENDER AIDE AND ASSISTANCE 4. WALK MY SMOKE COMPARTMENT 5. COMPLETE AND SEND FIRE DRILL CHECKLIST

300

WHAT DO ELEVATORS DO DURING A FIRE?

RECALL TO THE LEVEL OF EXIT DISCHARGE

400

WHAT IS THE MAXIMUM SIZE IN SQUARE FEET A SMOKE COMPARTMENT CAN BE?

22,500 SQFT

400

EXISTING HEALTHCARE FACILITY, IN A SPRINKLED BUILDING, WHAT IS THE REQUIRED SEPARATION/RATING OF HAZARDOUS AREAS FROM OTHER SPACES IN REGARDS TO WALLS?

SMOKE PARTITION, 19.3.2.1.2, CONTINUITY 8.4.2(3)

400

WHEN SEPARATING TWO SUITES WHAT MUST THE PARTITION BE CONSTRUCTED OF?

NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL, (LS 101 Chapter 18.2.5.7.1.4)

400

WHAT IS ON THE PICTURE?

Fire CheckList

400

WHEN I PULL A PULL STATION WHAT TWO THINGS DOES THIS DO?

IMMEDIATELY CALLS THE FIRE DEPARTMENT & NOTIFIES ALL OCCUPANTS WITHIN THE BUILDING

400

WHO DO YOU NEED DIRECTION FROM TO CLOSE A MED GAS ZONE VALVE?

RESPIRATORY OR A PHYSICIAN

500

WHAT IS A SMOKE COMPARTMENT? Simple version :)

A CONTINUOUS MEMBRANE

500

WHAT THREE TYPES OF EQUIPMENT ARE ALLOWED IN THE CORRIDOR ON A PATIENT FLOOR?

1. EQUIPMENT AND CARTS "IN USE" 2. MEDICAL EMERGENCY EQUIPMENT NOT IN USE 3. PATIENT LIFE AND TRANSPORT EQUIPMENT

500

MED GAS ZONE VALVES SHOULD HAVE THESE TWO THINGS LABELED AND LOCATED ON WHAT?

TYPE OF GAS AND ROOMS THE ZONE VALVE SERVES ON THE PIPE

500

This is the only month that starts with "Feb"?

WHAT IS "FEBRUARY"

500

WHAT THREE THINGS WOULD ACTIVATE THE BUILDINGS GENERAL FIRE ALARM SYSTEM?

MANUAL PULL STATION, SMOKE/HEAT DETECTOR, SPRINKLER WATER FLOW SWITCH

500

WHAT IS THE STANDARD TEMPERATURE A SPRINKLER HEAD WITH A RED FUSIBLE GLASS BULB NEEDS TO REACH TO BREAK AND DISCHARGE WATER?

150-155 DEGREES F