Seperations, Firewalls, Closures
Sprinklers...?
True or False
Odds and ends
100

The device attached to a closure that automatically returns the closure to its closed position

What is a self-closing device?


I was under the misconception that a self closing device was called a closure.

100

The NFPA Document that is used for compliance for the Installation of sprinkler systems in residential buildings with no other occupancy

What is 13R. A major cost reduction in comparison to having to conforming to NFPA 13.

100

In a non-sprinklered residential heat detectors are required in each dwelling unit  

False, in older Building Code versions this was a requirement. No longer the case.

100

2 of the 8 characteristics of magnetic locking devices that are part of an exit

3.4.6.16.4 *not high hazard

1. Has a F/A

2. F/A - Alarm releases door

3. Loss of Power releases door

4. releases immediately by authorized personnel switch

5. push of 90N will create a unlock sequence within 15 sec.

6. reset manually 

7. sign is required saying that it will release within 15s after force applied

200

A parapet wall that is at least 6 inches high is part of a fire wall that has this fire rating

What is 2 hours? 


A 4 hour fire wall will have a 3 foot parapet wall

200

Group D (offices and services)

6 storeys in height 3600 square metres


What is no sprinklers required.


3.2.2.55 construction measures must be met

200

When an occupancy that is anything other than high hazard industrial and reaches 50 persons, the exit doors must swing out- True or false

What is false? 


door swing comes into effect after 60 people

3.3.1.11

200

Occupancy type of laundry area of the Sheraton Surrey

What is F-2?

Medium Hazard

Found in Div B appendix A p 566-569

300

A refuse chute without automatic closure requires this fire separation rating for the discharge room

What is 2 hour?

3.6.3.3.2)b)

and 1 hour even if it does have an automatic closure

300

In a 6 storey building if the 3rd floor is required to be sprinklered, then these floor levels also require sprinklers

What are the floor levels below a sprinklered floor


3.2.2.18.2)

300

A restaurant in a sprinklered building with an occupant load of 30 or less is Classified as a D occupancy - business or personal services

What is true?

3.1.2.6

Also require occupant load sign

300

All building systems being equal who can have more workers in the same amount of space between a kitchen and a manufacturing shop

What is a manufacturing shop?

Occupancy load factor calculations are found in table 3.1.17.1

400

If a fire separation wall is required to have a 2 hour fire rating then the rating for a door in that wall is required to have this rating  

What is 1.5 hours

Table 3.1.8.4 shows all the relaxations, mostly by 30min

400

Single storey F-1 occupancy non-combustible construction

What is Sprinklered?

3.2.2.71

Becomes an issue when a business changes a process pushing its occupancy class from f-2 to f-1 

400

Exit capacity on a ramp with a 1:9 slope is more than an exit with a standard rise run ratio 

If the exits are of the same width

What is true


Exit width requirements are all found in 3.4.3

400

Occupancy type of Surery Pretrial

What is B-1 

Detention occupancy