Technician 101
Specifications
Tools
Safety
Advanced
100

Corrected using a single strike with your initials and date

What is how to correct a recording error?

100

Operating type where the component is connected to a wiring harness but not operating

What is Operating type 1.2?

100

This tool is creates a low resistance path for current to pass, it then can easily be measured.

What is a shunt?

100

Sort, Set, Shine, Standardize, Sustain

What are the 5S philosophies?

100

The RMS in Grms

What is ROOT / MEAN / SQUARE?

200

What the acronym DVP & R stands for.

What is Design Verification Plan and Report?

200

I/Jobs/Specs (Obsolete)(Reference)

Where you can find current library of test specifications?

200

This is set to assure your environmental chamber does not exceed a temperature extreme?

What is a product saver (Red Lion)?

200

The last line of defense to protect the safety of the employee

What is Personal Protective Equipment (PPE)?

200

Resistance is used in DC systems; this is it's equivalent for AC systems

What is Impedance?

300

Duration in hours to communicate to the client of a testing failure

What is 24 hours from discovery?

300

The area of the specification that determines if the DUT meets or does not meet expectations.

What is the acceptance criteria?

300

This piece of equipment is an electronic device that is capable of producing a repeating or non-repeating waveform.

What is a signal generator?

300

Only the person whom applied it can remove it

What is a Lock Out Tag Out (LOTO) lock?

300

This consists of two wire legs made from different metals to measure temperature.

What is a thermo couple?

400

The TMAX of a walk in chamber?

What is 100C?

400

PV

What is Production Validation?

400

This piece of equipment is commonly used to display and analyze the waveform of electronic signals

What is an Oscilloscope?

400

You can't bring this into the lab without approval and SDM review

What are chemicals?

400

An electrically operated switch that is activated by a current or signal in one circuit to open or close another circuit

What is a relay?

500

This is checked at the connector end, typically with a DMM

What is voltage output?

500

Typically, this vertical chart contained in the specification shows the path of testing the product must complete

What is the test flow?

500

For this type of resistance measurement, the voltage is measured at the DUT, voltage drop in the test leads is eliminated

What is a four wire resistance measurement?

500

The app where you find Intertek training modules

What is 10X Way Learning?

500

V=R/I

What is Ohms Law?