Indicators
Time
Temp and Pressure
Sterilization
Microbiology
100

The EO biological indicator is placed in the load

What is the center?
100

Recommended EO sterilization aeration time when the aerator is set at 140 degrees F

What is 8 hours?

100

Gravity steam sterilization can be rendered ineffective if the temperature is below _____ degrees F. 

What is 250 degrees F? 

100

Placed in a Frazier suction tip for proper steam sterilization.

What is distilled water in the lumen? 

100

Microorganism used within the biological indicator for ethylene oxide sterilization

What is Bacillus Atrophaeus? 
200

Biological indicator is placed where on the steam sterilizer cart

What is bottom front?

200

A frasier suction should be flash sterilized for this many minutes in a gravity steam sterilizer

What is 10 minutes? 

200

Minimum Fahrenheit temperature for sterilization to occur in a prevacuum steam sterilizer

What is 270-276 degrees?

200

Stripes on the steam chemical indicators change to what color when exposed to the sterilization parameters

What is black?

200

Occurs when cell destruction by steam sterilization

What is coagulation of protein? 

300

 Time after incubation that the EO biological indicator can be read.

What is 24 hours? 

300

Amount of time an item should be submerged in glutaraldehyde  

What is 10 hours? 

300

Required pressure for a steam sterilizer set at a temp of 250 degrees F

What is 15-17 pounds of pressure?

300

 A liquid chemical sterilant used for sterilizing endoscopes with a cycle time of 30 minutes.

What is Peracetic acid?

300

Steam sterilization biological indicator contains a heat resistant, spore forming Bacillus ________.

What is Stearithermophilus? 

400

The most reliable method for determining the efficiency of moist heat sterilizers is the controlled use of biological indicators containing this organism

What is Bacillus Stearothermophilus?

400

Steam biological indicator incubation period 

What is 24 hours? 
400

Instruments should not exceed  _______ lbs. to prevent density

What is 25 pounds? 

400

Item that should not be sterilized by dry heat.

 What is linens? 

400

Low level disinfectants kill most microbes with the exception of these

What is Spores?

500
Monitor that provides positive assurance of sterility 

What is biological? 

500
Wrapped instrument sets in a steam sterilizer set at 270 degrees F sterilized for ______ minutes. 

What is 4 minutes? 

500

Degrees Celcius that the steam sterilization biological indicator should read when incubated. 

What is 55-60?

500

Sterilizer that operates under conditions of exposure, exhaust, and dry cycles.

 What is gravity air displacement?

500

Term used for moisture penetrates through a sterile barrier. 

What is strike through?