ELCA
Angiosculpt
IVUS
Verrata
SyncVision
100

This must be flushed from the area of interest prior to performing laser atherectomy.

Contrast

100

How many sizes of Angiosculpt balloons are there (diameter)

Four (2.0, 2.5, 3.0, & 3.5)

100

IVUS can create vessel measurements in two ways.  What are they?

Area and diameter.

100

Verrata + pressure wires come in what 2 lengths?

185cm and 300 cm

100

What feature of SyncVision assists in visualizing the markers on a post-dilation balloon following a stent deployment?

Device detection.

200

The number of different sizes of ELCA coronary catheters.

4 (They come in a 0.9, 1.4, 1.7, and 2.0)

200
The different lengths an Angiosculpt is offered in.

6mm, 10mm, & 15mm

200

When using IVUS, there is a natural artifact that occurs on the screen during the initial live image.  This artifact can be removed by accomplishing what step?

Ringdown

200

When using a Verrata wire, one must first flush the wire, lay the wire flat on the table, and plug it into the PIM box.  What does the screen say is being accomplished as soon as the wire is plugged in?

Zeroing

200

SyncVision has the ability to enhance imaging using 2 technologies.  What are they?

Image stabilization and vessel analysis

300

When performing coronary laser atherectomy, this must cross the lesion before the laser should be used

A coronary interventional wire.

300

Angiosculpt is the only specialty balloon in the scoring/cutting category that is indicated for treating ISR in what type of lesion?

Complex type C lesions.

300

When using IVUS, what lesion type typically casts a shadow?

Calcium

300

When performing an iFR, what type of hyperemic agent is suggested?

None, iFR is performed without any hyperemic agent as it is a resting index.

300

True or False, SyncVision must be turned on and logged in before any imaging is accomplished in order to use any of its features.

True

400

When using the 0.9 x 80 ELCA, the laser can be in use for 10 seconds before this will happen.

A 5 second pause.

400

The shape of the scoring element edges on an Angiosculpt balloon.

Rectangular

400

IVUS is the only type of vascular imaging that penetrates deep enough to EFFECTIVELY visualize beyond what layer of the vessel?

Tunica Intima or intimal layer.
400

iFR measurements can be performed in the left main.  However, to do so, one may have to normalize where?

In the Aorta.

400

With iFR co-registration, one can virtually stent a vessel before actually opening what?

Any interventional equipment

500

This type of wire cannot be used for coronary laser atherectomy.

Hydrophillic

500

Angiosculpt is backed with what type of guarantee?

A no-cross guarantee.

500

When using IVUS co-registration, one can now determine what type of measurement that was not previously available with regular IVUS evaluation?

Length measurements.

500

When performing an iFR co-registration, the pullback is done under fluoro.  After this step, what must be accomplished to complete the iFR co-registration?

A contrast injection under Cine.

500

Dr. Kim's DJ name was what?

The Korea Kid!