Rules and Guidelines
Tools and Materials
Waste and Pests
All About Those Pipes
Measurements & Dimensions
100

When there is a conflict between the requirements of the Code and the manufacturers installation instructions, the ________ requirements shall apply.

a. Code

b. more specific

c. more restrictive

d. manufacturers

c. more restrictive

100

Materials used in plumbing systems must be listed by a(an) ________ agency.

a. evaluation services

b. third-party testing 

c. third-party certification

d. accreditation service

c. third-party certification

100

The approved methods for preventing rodents from entering a structure do not include ________.

a. caulking

b. strainer plates

c. building traps

d. meter box design

c. building traps

100

Standpipes that are part of a combined system shall be at least ________ inches in size.

a. 3

b. 4

c. 6

d. 8

c. 6

100

The code requires dimension #13 to be at least ________ inches. (Pic 2.)

a. 12

b. 13

c. 14

d. 15

d. 15

200

What is the minimum required capacity of a 2" sewage pump?

a. 15 gpm

b. 21 gpm

c. 30 gpm

d. 46 gpm

b. 21 gpm

200

The wrench best suited for piping up against a wall is #________. (Pic 1.)

a. 5

b. 4

c. 2

d. 1

c. 2

200

Soil and waste stacks shall be provided with a yoke relief vent in buildings having more than ________ stories.

a. 12

b. 10

c. 8

d. 4

b. 10

200

The number of threads per inch on standard steel pipe threads generally ________?

a. decrease as the diameter of the pipe increases

b. increase as the diameter of the pipe increases

c. does not vary with the diameter of the pipe

d. depends solely on the pressure the pipe must withstand

a. decrease as the diameter of the pipe increases

200

The minimum dimensions of a sump pit are ________ inches in diameter and ________ inches deep.

a. 16; 20

b. 18; 20

c. 18; 24

d. 20; 24

c. 18; 24

300

The Code allows a licensed Master Plumber to install up to ________ sprinkler heads off the domestic water in any one building.

a. 10

b. 15

c. 20

d. 30

d. 30

300

The material that should not generally be used for roof drains is ________.

a. wrought iron

b. lead

c. stainless steel

d. copper

a. wrought iron

300

Exposed overhead soil or waste piping is prohibited from being located in a ________.

a. medical clinic exam room

b. restaurant supply warehouse

c. soiled linen utility room in a hospital

d. storage pantry of a food service establishment

d. storage pantry of a food service establishment

300

Which statement is true?

a. soil piping can connect to a waste line

b. waste piping can connect to a soil stack

c. a sewage ejector can connect to a leader line

d. sump pumps can connect to a vent line

b. waste piping can connect to a soil stack

300

In order that a branch may be correctly termed a dead end, it shall be terminated by a fitting not used to admit liquids to the pipe and at a developed length of ________.

a. 1 foot or more

b. 2 feet or more

c. 3 feet or more

d. 4 feet or more

b. 2 feet or more

400

The water supply system test must hold a water pressure not less than ________.

a. 5 psi

b. 50 psi

c. 10-foot head pressure

d. 150 psi

d. 150 psi

400

The tool best suited for work in close quarters is? (Pic 3.)

a. 1

b. 2

c. 3

d. 4

b. 2

400

Indirect waste piping that exceeds ________ inches in total developed length shall be trapped.

a. 24

b. 48

c. 54

d. 72

b. 48

400

When more than one change of direction exceeding 45 degrees occurrs in a run of piping, only one cleanout shall be required for ________ feet of developed length.

a. 40

b. 60

c. 80

d. 100

a. 40

400

The wall area above built-in tubs w/shower and shower compartments shall be constructed of smooth, noncorrosive, and nonabsorbent materials to a height of ________ feet above the room floor level, and not less than ________ inches from the compartment drain.

a. 4; 46

b. 5; 58

c. 6; 70

d. 7; 82

c. 6; 70

500

On construction sites, ________ are required for workers.

a. water dispensers

b. emergency showers

c. emergency eye washes

d. toilet facilities

d. toilet facilities

500

The color marking for reclaimed water, irrigation, and slurry lines is ________.

a. purple

b. green

c. pink

d. white

a. purple

500

A high-efficiency urinal flushes at ________ gpf or less.

a. .5

b. 1

c. 1.5

d. 2

a. .5

500

PVC pipe when installed vertically requires a mid-story guide for pipe sizes ________ inch(es) and smaller.

a. 1

b. 3

c. 2

d. 1 and 1/4

c. 2

500

In the trade, we "Mickey Mouse" the waste and the water. For dimension #18, we like to keep the distance between Mickey's nose and his ear at ________ inches. (Pic. 2)

a. 2

b. 3

c. 4

d. 6

c. 4