E-21, SSPS, RPS
AMSAC
SPDS
Turbine Control Oil System
Excore Instrumentation
100

What is the purpose of these systems? 

To initiate the required protective action whenever a condition monitored by the system reaches a preset level to protect the three barriers to the release of radioactive materials

100

Is AMSAC safety related? 

AMSAC is non-safety related and not environmental qualified
100

What is the purpose of SPDS? 

Monitor and display plant parameters used for post-accident monitoring. 

100

What is the purpose of the tube control oil system?

Provide EH fluid used by DEHC system to control speed and loading of the main turbine by controlling opening of governor valves

provide equipment protection by closing all steam valves to interrupt steam flow to the main turbine if the reactor trips, the generator trips, of if there is a condition that could damage the turbine or the plant

100

What is the purpose of the NIS?

To measure the number of neutrons leaking from the core

200

How many channels of E-21 are there? Trains of SSPS?

4 channels of E-21

2 trains of SSPS

200

What does AMSAC stand for? 

Anticipated Transient Without Scram Mitigation System Actuation Circuitry

200

Is it safety-related? 

Not design class 1, nor meets single failure criterion
200

Which valves does the TCO system contain valve actuators for? 

Governor valves

Stop Valves

Interceptor valves

Reheat Stop valves 

200

What are the four ranges?

Source, Intermediate, Power, Post Accident (Gamma-metrics)

300

What is the position of the Rx trip bypass breakers (open/closed, racked in/out) during testing?

Racked in and closed to allow for trip testing

300

What is the purpose of AMSAC?

To inject turbine trip and equipment actuation signals independent of the SSPS

300
Where are they located? How many are there? 

2 per unit in control room 

2 in TSC 

2 in EOF

300

Where is the EH reservoir located? 

119' Elevation

300

What is the location of the four ranges?

Source: Bottom of core at 0 and 180

Intermediate: Middle of core at 0 and 180

Power: 45, 135, 225, 315

Gamma metrics: 90 and 70 

400

Name two inputs and two outputs of the SSPS system?

Inputs: Eagle 21, Nuclear Instrumentation, Seismic Instrumentation, Field Contacts, Manual Inputs

Outputs: RPS, ESFAS, Indications

400

When does AMSAC become armed? 

>40% Reactor Thermal Power

>32% Turbine Power

400

Where is the SPDS application hosted?

SPDS application is hosted on the transient recording system (TRS) in PPC room 

SPDS in TSC and EOF are connected to DCPP LAN and receive data from DMZ servers 

400

What is the purpose of the EH reservoir? 

Oil to the suction of the EH pumps

Acts as a surge volume of EH fluid for the EH system

400

How many channels and detectors are there for each range? 

Source: 2 channels, 1 per channel

Intermediate: 2 channels, 1 per channel

Power: 4 channels, 2 per channel

Post Accident:2 channels, two per channel

500

What does the reactor trip system do? What does ESFAS do? 

Reactor trip system automatically shuts down the reactor whenever the limits of safe operation are approached by dropping control rods in the core

ESFAS performs protective actions to mitigate the consequences of postulated accidents: Safety Injection, Phase A and B containment isolation, steamline and feedline isolation, aux feedwater actuation

500
Once already armed, what must happen happen for it to trip? 

3 of 4 steam generators have been at or below the 11% NR level set point for greater than 25 seconds 

500

Name 2 SPDS screen requirements.

Concise display, rapid response, reliability, data validity, convenient location, continuous display, isolation from safety systems, procedures and training, selection of information for display, human factors, minimum plant parameters for display

500

The TCO system must be able to prevent what two events from occcuring? 

Excessive cooldown

Overspeed condition 

500

What is another name for a source range instrumentation? Intermediate? Power?

Source: BF3 proportional counter

Intermediate: Compensated ion exchanger

Power: Uncompensated ion exchanger