A
B
C
D
E
100

When did installation of the first fully isocentric linear accelerator in the United States occur?


1961

100

Depth of maximum dose for a 6 MV beam is _____ below the skin surface.


1.5cm

100

Lipowitz metal is composed of which of the following? 


BLT + C

Tin, Bismuth, Lead, Cadmium

100

Orthovoltage x-ray machines have energies in the range of which of the following?


150kv to 500kv

100

Depth of maximum dose for a 15 MV beam is _________ below the skin surface.


3cm

200

In radiation therapy, which material interacts with the radiation beam to mimic those of tissue?


Bolus

200

What is used in shaping the field of an electron beam treatment?


Cerrobend cutout

200

What is the melting point of Cerrobend?


165° F

200

What opposing field technique is specifically designed for treatment of the breast?


Tangential fields

200

When should informed consent be obtained?

Before patient receives treatment 

300

Individual treatment doses may be defined as which of the following?


Fractionation
300

What is an anterior oblique and posterior oblique treatment field an example of?


Parallel opposed portals (POP)

300

A shifting field arrangement (feathering) often used in treatment of the brain and spinal cord is used primarily to

Prevent "hot" spots
300

What is the series of documentation and activities performed with the purpose of optimizing patient care?


Quality assurance (QA) program
300

When treating with electrons, the carousel rotates to place a _________________ in the beam to spread it out.


Scattering foil

400

Which treatment unit has the least amount of skin sparing?


Orthovoltage

400

The circulator in a linear accelerator does what?

Isolates the klystron from reflected microwave power


400

At what rate does the cobalt 60 source decay?


1% per month

400

What are the two photon energies emitted by cobalt 60 are _______ MeV.


1.17MeV and 1.33MeV


400

What is the half-life of a cobalt 60 source?


5.26 years

500

What is the purpose of a bending magnet in an accelerator?

A bending magnet deflects electrons 90 to 270 degrees toward the target.


500

For the order x-rays travel through the linear accelerator, what comes first?

Bending magnet or target?

Bending magnet

500

For the order x-rays travel through the linear accelerator, what comes first?

Primary collimator or flattening filter?

Primary collimator

500

For the order x-rays travel through the linear accelerator, what comes first?

MLC or Ion dose chamber 

Ion dose chamber

500

True or false?

Is the bending magnet found in the head of the accelerator?

True