Egress
Fire Safety
Site Development
Foundations
Floors
100

This is required to be at least 36 inches wide.

What is a hallway?

100

A self contained device that provides smoke detection and emits a loud sound.

What is a smoke alarm?

100

Subject to a 1 percent or greater chance of flooding in any given year.

What is a 100 year floodplain?

100

Typically sand, crushed rock, clean gravel, or a mix of granular materials.

What is structural fill?

100

The proper and successful transfer of building loads to the foundation.

What is the load path to the foundation?

200

The path of travel from any location in a dwelling to the exterior.

What is the Means of Egress?

200

The code stipulates that this is provided by the building wiring system, 

and these are used for backup.

What are primary power and batteries for smoke alarms?

200

Measured from the building face to the closest interior lot line.

What is fire separation distance?

200

28 days

Code required minimum duration for concrete to reach 2,500 PSI strength.

200

L/360

What is allowable deflection?

300

Must be able to be opened without a key or special knowledge.

What is an exit door?

300

In each sleeping room.

Outside each sleeping area.

On each additional story of a dwelling.

What are the locations for installing smoke alarms.

300

This shall fall a minimum of 6 inches within the first 10 feet.

What is surface drainage away from a building.

300

This protects foundations from the expansive effects of freezing and thawing soil.

Placing footings below the frost depth.

300

The distance for which a joist is selected.

What is an allowable joist span?

400

Can be a maximum of 7 3/4" below the top of a threshold.

What is a landing?

400

The code requires this to be installed in townhouses.

What is an automatic fire sprinkler system?

400

The agency that manages the National Flood Insurance Program.

What is FEMA?  Federal Emergency Management Agency.

400

2,500 PSI

The minimum compressive strength of concrete used for footings.

400

Supported at one end and allowed to span at the other end.

What is a cantilever?

500

A minimum of 10 inches and a maximum of 7 3/4 inches.

What is a stair tread and a stair riser?

500

Three methods that provide occupants time to safely exit a building in the event of fire.

What are smoke alarms, fire sprinkler systems, and fire resistant materials?

500

1,500 PSF

What is the lowest allowable load bearing pressure on soils?

500

This resists lateral and uplift forces acting on the framing system of a building.

What is foundation anchorage?

500

No longer than one-third of the depth of the joist, and shall not be located in the middle one-third of the span.

What are notches?