Abatement Full
RO, injects and interlocks
Pump Full
Abatement and pump Lite
and safety questions
Jose Questions
100

What are 3 specialty heads and what is special with them?

Sure

100

What 3 values do you watch while doing RO

RO, Backpressure gauge, fuel flow

100

Why do you take the N2 off of any IXH pumps?

Incase it has the 50 if stop
100

2 ways to purge an iAtlas

System purge and the other way

100

Does anyone play league of legends? I need one more competent person for a clash team

Slide into my DM's if you do

200

What is a dead give away that an abatement is probably a 2.1, 2.6, or 2.7?

CDA on the D port. HAS to be the D port

200

What are the 3 ways to adjust RO

Throttle control valve, Needle valve on premix fan, premix fan speed on HMI

200

If a pump does not have 50 if stop, how do you put the 50 if stop on it?

N2 regulator one time adjustment, and the config

200

Why do you wait before disconnecting all facilities

To wait for the pump to cool down

200

Whats the best nascar racer?

Dale Earnhardt, do it for dale boi

300

On RO with a head that has a capped inlet, what are you supposed to do with the injects and why?

Remove them because they are N2 high pressure purges and are flowing N2

300

Name 5 interlocks, what alarms they send out and where to find them

:D

300

If your gate valve is greyed out after a pump exchange on the HMI, and it is unresponsive, what do you need to do?

Cycle gate valve with PDT

300

What are the 8 loto points on an iatlas

N2, O2, CDA, NG, bypass manual iso, water drain, tape over the green button, power

300

Whats the best fruit?

Pomegrante

400

What would you check if your abatement didnt want to light after a PM? 3 major things

Screw inside ignitor caps, Ignitor, Pilot gas

400

On a etch head crowned system that has bypasses on 2 and 5, and crowns on 1,2,3, and 4,5,6, what buttons do you press while doing injects for inlet 6?

Pump run 5, clean 5

400

Describe how to do a full leak check on a brand new bypass thats already installed

O.o

400

What do you make sure the pump doesnt have before pressure leak checking to the abatement, to prevent an overpressure event. 

The pump N2 dilution (pump purge)

400

Best holiday?

Halloween

500

What and specifically where would you check if you had an abatement went down for high ADT temperature?

Around heat exchanger or the iso valves for PCW

500

Assuming theres no leaks, what are some major ways N2 or extra oxygen can get into the system? (at least 3)

bypass, purges, atomizer

500

What do you leave disconnected until as late as possible on a pump and why?

The ethernet, because similar IP's could bring down a live pump

500

What are 3 different measurements for vacuum?

Torr, Inches of mercury, inches of water, pascal

500

Worst alcoholic drink?

White claw/seltzer. Lemon White claws taste like someone waved a lemon on top of the white claw and that was almost too much flavor