100

This engineering organization founded in 1894 focuses on advancing human well-being for the built environment.

ASHRAE

100

This is the maximum airflow that can be transferred to any room from a corridor in hospital buildings.

25 CFM or 10% 

100

This is used in hospital and lab buildings for precise and accurate Zone airflow control

Venturi Valve

100

This field of engineering is concerned with the properties of gas-vapor mixtures. We can thank Mollier for this one!

Psychrometrics

100

This acronym refers to Arup's globally aligned set of Revit templates, content & parameters.

What is GRS (Global Revit Standards)?

100

Manufacturers catalog their product's environmental impact in these types of documents.

What are Enviromental Product Disclosures (EPDs)

200

Environmental air duct exhaust shall terminate not less than this distance from a forced air inlet.

2022 CMC, Section 502.2.1

10'-0"

200

Adding this component to 90deg metered elbow results in a lower pressure drop in comparison to a smooth radius elbow

Turning vanes

200

This component maintains high efficiency and expanded low temperature operation in outdoor DX units by preventing wind from blowing in 

Wind baffles

200

Interchangeable with practical or functional, airflow rate is commonly derived from this type of load

Sensible Load

200

The air velocity for horizontal mains must not exceed this value for acoustic concerns

1200 fpm - 1500 fpm

200

This building certification is the world's most widely used green building rating system

LEED

300

Though commonly referred to as "Title 24", the California Energy Code is formally designated Part what of Title 24: Building Standards Code

Part 6

300

The equal friction method calculates a maximum system pressure drop rating per 100'-0" of duct via the following criteria

Total system airflow and maximum velocity

300

The typical minimum duct length required downstream of fans to achieve fully developed flow

3 duct diameters

300

The three metrics determined by the Fan Affinity Laws

Airflow, pressure, and power consumption

300

This component is typically required under any piping or cooling equipment located within an IDF or electrical room

Secondary drain pan

300

Greenhouse gas's ability to trap heat within the atmosphere compared to Carbon Dioxide (CO2) is characterized by this metric

Global Warming Potential (GWP)

400

Parking garage exhaust shall not be required for enclosed parking garages given either of these 2 conditions apply (name at least 1)

2022 CMC, Section 403.7.1

Floor area is less than 1,000 SF or 5 or less vehicles are stored in the parking garage

400

Exterior zones typically extend a maximum distance of this far out from exterior walls

15'-0"

400

General exhaust from shower to be stainless steel roughly till this point of duct.

The branch duct to shower/ Approximately 50% dilution

400

Component in mechanical refrigeration systems that transforms high pressure vapor into high pressure liquid.

Condenser

400

Fire smoke dampers are exempt in this type of exhaust fan system tied to emergency power

Sub-duct

400

Buildings are responsible for this percentage of electrical consumption in the United States

https://tinyurl.com/4zp8zh4u

40%

500

Ventilation is permitted to reduce to zero in select few occupancy categories when spaces are in this operating mode

2022 CEC, Section 120.1

Occupied-standby

500

Rectangular duct above this aspect ratio is typically more expensive and less acoustically efficient

3:1

500

To avoid frequent tripping of FSDs, a high temp fusible link option FSD or heat detector in lieu of a smoke detector is preferable in this type of duct application

Dishwasher exhaust/TYPE II exhaust

500

The common factor that is used in load calculations that is a product of the specific heat times the density times the number of minutes per hour.

Specific heat capacity of air Or 1.08 

500

~18" clearance is required at the top and side of this item. Utilities may pass over it every ~6'-0".

Cable trays

500

A building's carbon footprint is most accurately measured by evaluating these 2 types of emissions occurring both during and after construction

Embodied and operational carbon