GROUNDING ELECTRODES
BOX FILL
BRANCH CIRCUITS
EQUIPMENT GROUNDING
GROUNDING METHODS
100

WHEN INSTALLING GROUNDING RODS, WHAT TYPE OF MATERIAL IS FORBIDDEN?

ALUMINUM

100

A #12 AWG conductor takes up ______ cubic inches for box fill?

2.25 cu in

100

A MULTIWIRE BRANCH CIRCUIT CONSISTS OF TWO OR MORE UNGROUNDED CONDUCTOR WITH _______ BETWEEN THEM?

VOLTAGE

100

#12 AWG CONDUCTORS ARE ATED FOR _____ AMPS AS AN EQUIPMENT GROUND?

20 AMPS

100

ELECTRICAL SYSTEMS THAT ARE GROUNDED SHALL BE CONNECTED TO _______ IN A MANNER THAT WILL LIMIT VOLTAGES FROM LINE SURGES, LIGHTNING STRIKES, OR CONTACT WITH HIGH VOLTAGE LINES.

EARTH

THE GROUND

200

WHEN INSTALLING TWO GROUNDING RODS ONLY AS THE ELECTRODES, WHAT IS THE MINIMUM SIZE GROUNDING ELECTRODE CONDUCTOR REQUIRED?

#6 AWG

200

A #6 conductor takes up _____ cubic inches for box fill?

5

200

A MULTIWIRE BRANCH CIRCUIT HAS TWO UNGROUNDED CONDUCTORS AND A NEUTRAL. THE VOLTAGE BETWEEN THE NEUTRAL AND EACH PHASE CONDUCTOR IS ______?

EQUAL

200

#10 AWG CONDUCTORS ARE ATED FOR _____ AMPS AS AN EQUIPMENT GROUND?

60 AMPS

200

NAME TWO APPROVED METHODS OF CONNECTING GROUNDING AND BONDING?

LISTED PRESSURE CONNECTORS

EXOTHERMIC WELD

OTHER LISTED MEANS

MACHINE SCREWS


300

WHEN INSTALLING A UFER GROUND ONLY AS THE ELECTRODES, WHAT IS THE MINIMUM SIZE GROUNDING ELECTRODE CONDUCTOR REQUIRED?

#4 AWG

300

THREE #14 AWG AND ONE DUPLEX RECEPTACLE ARE INSTALLED IN A BOX. WHAT IS THE MINIMUM CUBIC INCH CAPACITY ALLOWED?

18 CUBIC INCHES

300

A HOUSE HAS ONLY ONE BATHROOM AND THE BATHROOM HAS A SINGLE CIRCUIT DEDICATED TO THE POWER OUTLET IN THAT BATHROOM ONLY. MAY ANYTHING BE ADDED TO THIS CIRCUIT? IF SO, WHAT?

YES

EQUIPMENT IN THAT SAME BATHROOM ONLY

LIGHTS

EXHAUST FAN

OTHER EQUIPMENT IN BATHROOM

300

#6 AWG CONDUCTORS ARE ATED FOR _____ AMPS AS AN EQUIPMENT GROUND?

200 AMPS

300

THE GROUNDING ELECTRODE CONDUCTOR CONNECTS THE GROUNDING ELECTRODES TO THE _______ AT THE MAIN SERVICE?

SYSTEM NEUTRAL

NEUTRAL

GROUNDED CONDUCTOR

400

WHEN INSTALLING A UFER GROUND, WHAT LENGTH OF GROUNDING ELECTRODE CONDUCTOR IS REQUIRED?

20 FEET

400

NAME FOUR LOCATIONS IN A DWELLING UNIT WHERE GFCI PROTECTION IS REQUIRED FOR OUTLETS?

KITCHEN   GARAGE    BATHROOM     OUTDOORS

CRAWL SPACES    BASEMENTS   BOATHOUSES   LAUNDRY AREAS    WITHIN 6 FEET OF A SINK, TUB, OR BASIN


400

ARC FAULT PROTECTION IS REQUIRED FOR ALL ______ VOLT ______ AMPS OUTLETS IN THE BEDROOM, KITCHEN, FAMILY ROOM, DINING ROOM, LIVING ROOM, PARLOR, LIBRARY, DEN, SUNROOM, RECREATION ROOM, CLOSETS, HALLWAYS AND LAUNDRY AREAS OR SIMILAR ROOMS.

120 VOLTS / 15 & 20 AMP

400

GROUNDING SCREWS MUST BE ______ TYPE OF SCREWS?

MACHINE SCREWS

400

WHEN THE MAIN BONDING JUMPER IS A SCREW ONLY, THE SCREW SHALL BE IDENTIFIED HOW?

WITH A GREEN FINISH

500

WHAT TYPE OF ELECTRODE, WHEN PRESENT, REQUIRES A SUPPLEMENTAL ELECTRODE, AND REQUIRES TO BE SIZED BASED OFF OF TABLE 250.66

METAL WATER PIPE

500

YOU NEED TO ORDER A JUINCTION BOX FOR THE JOBSITE. THE BOX HAS A 4 INCH AND 2 INCH ENTERING FROM ONE SIDE AND A 4 AND 2 INCH ENTERING FROM AN ADJACENT SIDE OF THE BOX. IN THIS ANGLE PULL, WHAT MINIMUM SIZE BOX IS REQUIRED?

26 INCHES SQUARE MINIMUM

500

NAME TWO LOCATIONS WHERE LIGHTING OUTLETS ARE REQUIRED IN A DWELLING UNIT?

ABOVE STAIRS

EVERY HABITABLE ROOM

OUTDOOR ENTRANCES

HALLWAYS

GARAGES

500

WHEN UPSIZING CABLES DUE TO VOLTAGE DROP, THE EQUIPMENT GROUNDING CONDUCTORS MUST BE INCREASED ____________ TO THE CIRCUIT CONDUCOTRS?

PROPORTIONATELY

THE SAME AMOUNT


500

MAIN BONDING JUMPERS MAY BE A BUS, A SCREW, OR A _______?

WIRE

OTHER SUITABLE CONDUCTOR