Pump
Abatement
Procedure
Troubleshooting
Jose Questions
100

How do you fingerprint an IXM pump?

Once when you default, once when you config with max speed, once when you reduced speed

100

What are all the LOTO Points?

Gas, N2, O2, CDA, Power, Bypass manual iso valve, Green button

100

Whats the first paperwork you should verify before work?

The PPE matrix, comparing that to the WO

100

GV button in HMI is greyed out, why and how to fix this issue. 

communication between the pump and PGV needs to be set, use PDT to cycle the GV to set the communication. 

100

Freebee

yippee

200

Whats the IP address on an IH pump?

None, no synergis

200

What are the 2 ways to purge an abatement?

System Purge, and then the long way

200

How do you know if your tool is a dragon tool, and whats the PPE requirement?

Full acid suits, and respirator even during wet side

200

after installing a New pump, the pump is saying "Pump inverter is too hot"

Bad pump, replace

200

Whats my favorite cuisine of food?

Japanese

300

How do you do an exhaust pressure zero?

Probably right
300

What are the 3 ways used to adjust RO? 2 are valves, one is a setting

Butterfly valve, premix fan set screw, and premix fan screw

300

How do you know what kind of orings to use?

Specialty Oring spec

300

How do set up 50 If Stop on a pump that didnt have one?

Set the N2 regulator to 50, and then install the config

300

Which ones better? Shower Sprite, Shower Dr. Pepper, Shower Beer, or Shower Whiteclaw

Shower sprite

400

CDT and AVX are both reactive. How are both reactive

with contact with water, one turns into fire, one turns into poison
400

When does a 2 position valve high flow activate? In other words, what other function is it tied to?

Head clean?

400

How do you setup an abatement for RO?

Make sure atomizer is turned off, N2 Purges are off, bypass's dont roll because abatement is in HMI mode, head purges are capped off, CDA is off, all capped inlet lines are capped. 

400
How do you prepare a pump for FOI?

Do the return on stores, write in the comments: "Hold for FOI" and do the same for the EcUDL, then send the email and tell amber

400

What is the best reptile for swinging over your head like a bola, then throwing?

Iguana

500

Explain how to do leak checks from pump to abatement (high detail)

Yea

500

How much should you fill the packed tower with media?

300mm below the packed tower spray lance, or 12 inches. Mr beef

500

When should you use SPM flex's?

Dragon or EDT tools

500

What are some reasons (At least 5) your brand new pump isnt basing down

Yes

500

Jose VS Giraffe, who would win

Jose obviously