Pubs
Abbreviations
Fueling
Emergency Procedures
EP's/ GK Cont'd
100

Daily Deck

A1-F18EA-MRC-200

100
FLIR

Forward Looking Infared

100

Primary oil used for servicing

MIL-PRF-23699

100

APU Fire

Signal pilot, lazy 8 (3-5 sec), if unsuccesful pull APU emergency switch in NWW, if unsuccesful go into door 13l and pull APU prime circuit breaker, if unsuccesful spray FEA off MLG door into APU cavity.

100

Hot Brakes

Signal Pilot Hot Brakes, Taxi pilot Away from personnel IE:wash rack, all personnel clear 300 ft, approach from fwd/aft only, portable fans may be used for rapid cooling, if flames are present spray fea


200

Cleaning and Corrosion

NAVAIR 01-1A-509

200

OBOGS

On Board Oxygen Generating System

200

How many people are required for fueling and where are they

3, 1 on the fire bottle, 1 on the hose, and 1 in the cockpit
200

AMAD Fire

Signal pilot, lazy 8 (3-5 sec), Pilot uses internal extinguisher, Open door 54 L/R spray FEA

200

what is the minimum psi for Apu operation?

Below -15 degrees 3,000, -15 degrees and above 2,500 

300

Aircraft tires and tubes

NAVAIR 04-10-506

300

RAT

Ram Air Turbine

300

What is the minimum fuel settling time

2 Hours

300

Internal engine fire

Signal pilot, lazy 8 (3-5 sec), windmill 5 min, spray FEA off wall into intake

300

what type of chain do we use and what is its maximum weight capacity for a breaking load

TD-1B and Breaking load is 16,000 ibs

400

Hydraulics Manual

NAVAIR 01-1A-17

400

JHMCS

Joint Helmet Mounted Cueing System
400

If the engine needs service, should you service it cold?

No, turn on and windmill engine or service after next flight

400

External engine fire

Signal pilot, lazy 8 (3-5 sec), pull fuel shutoff valve in MLG, open doors 65/69 L/R, spray FEA into door 65 having it vent through 69

400

Battery spill

Secure all external power, clear all unauthorized personnel from area, notify maintenance of battery spill where they can call fire department, grab spill kit then don PPE, man the fire bottle until relieved 

500

Support Equipment cleaning, prevention, and corrosion control

NAVAIR 17-1-125

500

DFIRS

Deployable Flight Incident Recorder Set

500

When fueling if you must stop for any reason how long must you wait to allow dissipation of any static charge?

1 minute

500

Emergency egress

Signal pilot to make sure he is concious, pull fuel shuttoff valve in MLG, drop the ladder, open the canopy electrically manually or forceibly, safe the seat and disconnect the straps, pull pilot out, slide pilot down the horizontal stabs feet first

500

All 17 Delta P locations

1 in NLG, 3 in MLG, 2 in APU, 1 in each AMAD, 1 in each Engine , 2 in each engine fuel filter