100

Customer sets up this analyzer setting based on their SOP flags

User Defined Abnormal Flagging

100

This is a concentrated version of DCL

DST

100

The fitness expense is reimbursed on this yearly basis

Calendar year

100

I need this document to troubleshoot SP-50 smear and stain issues

SP-50 troubleshooting guide

100
You get to an implementation for a non CWS XN3100 and it is missing the SP rules tab, what do you do

Call service. Install was not done properly

200

Where can you locate the document with the correct Q-flags? 

Q-flags PN on CRC

200

I am an additional channel found on the XN20, that differentiates abnormal lymphocytes from Blasts

WPC Channel

200

I can find details for Sysmex's restrictions on travel and expense on this document

Sysmex Travel and Expense Policy

200

I can adjust this setting when I see peeling on a slide made on the SP-50

Rinse count and service settings rinse setting

200

The XNIC workbook is sent to this team after being filled out with the customer 

ITAC

300

This stop condition usually has to be deselected prior to running CAP surveys or proficiency tests

Unregistered QC 

300

This is the open stability for XN-CHECK QC

14 days

300

Expense reports must be approved by this day and time to be sent for payment

Tuesday at 4pm CDT

300

This is where the grading limits in the cellavision are derived

ICSH grading limits

300

XN9100 with 3 XN-10s is requesting that all XNs want to be connected to the same IPU because they only have one port available. What happens next

Can't do that. Only 2 XN-10s/20s can be connected to one IPU at a time

400

This is where I can find my uncorrected WBC count on the XN

TNC on service tab

400

This is the diluent for the Retic channel

DFL

400

This is where I go to pay chase any personal expenses charged to my corporate card

400

This is the major difference in staining methodology between the SP10 and the SP50

Bath staining on the SP50 vs single slide staining by the SP-10 
400

This is the full name for SNCS

Sysmex Network Communications System
500

The reason WBC-D is present on the reportable range study

Validates the WDF channel responsible for diffs and Low WBC reflex
500

This is the stain present in PLT-F reagent responsible for endoplasmic staining

Oxazine

500

I would reach out to this person if I had an issue/question with my corporate card, expense report or reimbursement

Minnie Newell

500

This is the reason why I am unable to enter rbc grading limits for my user defined morphologies 

Didn't select a user group

500

This where I can locate the IP addresses for a CWS customer

CWS settings document