Hardware and Materials
Tools used in Residential wiring
Intro to Electrical Service
General NEC Requirements
Branch circuits
100

 The ____________ is the system used to size the conductors used in residential wiring.

American Wire Gauge

100

A(n) ___________ ,made from non conductive nylon or steel, is used to pull wires or cables through electrical conduit.

fish tape

100

 Ground rods must be at least ______________feet long.

8 FT 

100

Receptacles that are installed to meet NEC® Section 210.52 placement requirements are not permitted to be more than _______ feet above the floor.

5 1/2

100

The NEC requires that small-appliance branch circuits be protected with _______  ampere overcurrent protection devices.

20 amp

200

The article in the NEC® that covers nonmetallic sheathed cable is Article _________



Article 334

200

 A(n)_________ is used to cut holes in wallboard for boxes and to cut plaster and lath for box installation in remodeling work.

 keyhole saw, sheetrock knife (saw)

200

 Underground service conductors are required to be buried at least _______  feet by the NEC. 

2 ft or 24 inches

200

Lighting fixtures weighing no more than______ are permitted to be supported by outlet boxes.

50 lbs

200

The NEC requires that bathroom branch circuits be protected with _______  ampere overcurrent protection devices.

20 amp

300

 When using aluminum conductors,______________  size conductor must be used to carry the same amount of current as a copper conductor

Larger

300

11. A drill bit with a spiral cutting edge used to bore holes in wood is called a(n) ____________ bit.

Auger 

300

The overhead service conductors from the last pole to the point connecting them to the service entrance conductors at the building are called conductors.

Service Drop Conductors

300

Where device boxes are installed in walls or ceilings that have a noncombustible surface, the edge of the box must be no more than _____of the wall or ceiling surface

1/4'' 

300

The NEC requires a laundry branch-circuit to be rated at ____amperes.

20 amps

400

Type _____________ cable is used for underground installations of branch and feeder  circuits.

UF cable 

400

When drilling holes in wooden framing members, electricians often use a ___________ drill easier in the tight spaces they sometimes encounter between framing members.

Right angle drill 

400

 Copper coated steel ground rods must be listed and be at least _________ in diameter.

1/2 ''

400

 Individual wall spaces of_____ feet or more in width are considered usable for the location of a lamp or appliance, and a receptacle outlet is required

2 ft ,  two

400

 The NEC requires the majority of motor applications to be protected by overload devices sized not more than ______ of the motor's nameplate current rating.

125 %

500

Type _____________ cable is used for underground service entrance installations.

USE Cable

500

The information found on a power tool's _________ includes the catalog number of the power tool, the voltage, the amperage, the revolutions per minute (rpm), and the weight of the power tool.

nameplate

500

What is the minimum size cable needed for a 200 Amp overhead ervice 

4/0 awg

500

For interior stairways that have________ or more risers, a wall switch must be installed at every floor level and landing to control the lighting outlet(s) located there.

6 stairs

500

Most residential electric water heaters operate on 240 volts, are wired with ______AWG conductors, and are protected with a _____ampere overcurrent protection device.

10 awg ,  30 Amps.