PPE
To respirator or not
RP Coverage
DAC
Misc.
100

When should you list the specific brand names for radiological suits?

Never

100

Where are respirator requirements listed?

No place. GD-00016 says to "consider" the use of respiratory protection for things like "entry into airborne radioactivity areas". But it isn't explicitly spelled out in any procedure.

100

Which RWP types require RP Coverage?

Job Specific and ALARA 

100

When must you include DAC values on your RWP?

When air monitoring will be performed.

100

True or False:

All RWPs must have Removable Contamination and General Area dose rate values.

True

200

Select radiological protective clothing based on _______ risk, environmental hazards, and non-radiological considerations. 

radiological

200

True or False:

The Maximum Use Concentration or MUC for each type of respiratory equipment is calculated on an 8 hour Time-Weighted-Average and not to peak, short-term levels. Therefore, it is very unlikely that a MUC will be exceeded.

True

200

True or False:

Actions performed solely to support entry/exit from an area are considered part of RP Coverage.

False

200

At what percentage of the DEFAULT alpha DAC value do we post an ARA?

10%

200

True or False:

All RWPs must have Work Documents listed

False (only Job Specific and ALARA)

300

Disposable suits are broken down into two categories. What are they?

Permeable and Impermeable

300

What document governs the Respiratory Protection Program?

DND-IH-PRO-00028, Respiratory Protection Program

300

Stand-alone characterization surveys performed prior to the work activity do not fulfill the ___________ requirement, when specified on an RWP.

RP Coverage

300

At what percentage of the Beta DAC value do we post an ARA?

30%

300

Who approves Job Routine and Job Specific RWPs?

RP Supervisor & Line Manager

400

Hot work and therefore fire-resistant PPE should be on a separate ____.

Task

400

What is the MUC for a full face respirator?

5 DAC

400

_________ ____________ is intended to provide one or more RCTs who continuously monitor radiological conditions.

Continuous Coverage

400

What is the definition of DAC?

Derived Air Concentration--the concentration of a radionuclide in air that if breathed by a person for an entire working year would irradiate them to their occupational limiting condition (5 rem). 

400

Which two additional approvals are required for ALARA RWPs?

RPE and RPSM

500
Which procedure provides guidance for the selection of radiological PPE?

RP-PRO-00032, Selection of Radiological Protection Clothing

500
What is the MUC for a PAPR?

100 DAC

500

What does it mean "to monitor" radiological conditions?

To perform surveys over a period of time

500

If I were to stand in an area (for 2000 working hours) that has 1 DAC airborne radioactivity concentration, I would receive how much exposure?

5 rem


500

During use of the RWP ______ _______ must be evaluated to determine if existing controls remain effective.

radiological data