Electric Motors: Single-Phase and Polyphase
Motors: General Knowledge
Motor Branch Circuit Over-current Protective Devices
Locked Rotor Current & Phase Loss for Motors
Motor Feeder Conductors, OCPDs, and Tap Counductors
100

True or False: A DC motor consists of a field circuit and an armature circuit.

What is True?

100

The current from ___ is used to determine the branch circuit conductor size for a DC motor.

What is T.430.247?

100

A 2-pole breaker in a 120/208-V, 3-ph, 4-W panel supplies power to a circuit. This circuit is connected to a 2 hp, 208-V, 1Ø motor. A safety switch is to be installed adjacent to the motor. DETD fuses with a maximum permitted rating of ___ A can be installed in the switch.

What is 25?

100

___ current is the amount of current that flows in the circuit conductors when a motor is first energized and the shaft starts to rotate.

What is starting?

100

A ___ AWG conductor is the smallest that can carry 116 amps.

What is 1?

200

___ is the turning force exerted on the armature in a motor.

What is Torque?

200

Motor Nameplate Information:  208-230/460-V     3Ø     100 hp    

Supply:  3-pole breaker in a 120/240-V, 3-ph, 4-W panel

Minimum size circuit conductors are ___ AWG.

What is 350?

200

A ___ circuit carries the electric signals directing the performance of the controller but does not carry the main power current.

What is control?

200

___ is when one leg (phase) of a 3-phase system is lost.

What is single-phasing?

200

The key to determining the ___ rating of a motor feeder OCPD is to first determine the maximum permitted size or rating of an OCPD of the same type that would be used for the largest motor connected to the feeder.

What is maximum?

300

A ___ motor can operate on either AC or DC power.

What is universal?

300

The nameplate for a 15 HP, three-phase motor shows an FLA of 35 amps at 230 volts. What minimum size SOO cord is required to connect the motor to the branch circuit?

What is 4?

300

The OCPD for a motor branch circuit provides conductor protection against ___.

What is short circuit and ground fault currents?

300

A(n) ___ is a small pump connected to a system and is intended to maintain pressure in the piping system to an artificially high level.

What is jockey pump?

300

Fuses are installed in the ___ and used to protect the tap conductors against overload and the motor against short circuits and ground faults.

What is safety switches?

400

A motor in a(n) ___ enclosure can be used outdoors.

What is TENV?

400

The current from ___ is used to determine the branch circuit conductor size for a 1Ø motor.

What is 430.248?

400

The SC & GF protective device opens very quickly in response to high ___ caused by fault currents (SC or GF).

What is current levels?
400

Energized parts within control cabinets and other control enclosures used for fire pump systems shall be ___.

What is located at least 12" above the floor level?

400

The OCPDs at the termination of the motor feeder tap conductors are required to be sized to ___.

What is protect the motors?

500

A 1Ø motor is pulling 13 amps when connected to a 240-volt circuit. You know that this type of motor is about 60% efficient and has a power factor of .88. The motor is delivering about ___ hp.

What is 2.2?

500

Motor Nameplate Information:  115/230-V     1Ø     3 hp    

Supply:  1-pole breaker in a 120/240-V, 3-ph, 4-W panel

What minimum size SJ cord is needed to connect this motor?

What is 7?

500

Despite being banned in residential uses, ___ inhibits rust and corrosion of iron and steel so it may still be used on bridges, railway equipment, ships, lighthouses, and other structures.

What is lead-based paint?
500

A fire pump is permitted to be supplied by ___ the main distribution (service) panel.

What is a fused safety switch connected ahead of?

500

A three-phase, 240-volt feeder is going to supply power to one 5 hp 3Ø motor, three 2 hp 3Ø motors, and two 1 hp 3Ø motors. The minimum size aluminum THWN/THHN conductors permitted for this feeder are ___ AWG.

What is 6?