Screws or bolts for securing floor-mounted fixtures shall be?
Copper alloy 402.3
The minimum capacity for a storage water heater is
based on the “first hour rating” and the number of bedrooms and bathrooms
501.1 and Table 501.1(1)
Under certain conditions, traps serving sinks that are part of the equipment of bars, soda fountains, and counters
need not be vented
902.2
Each plumbing fixture trap shall be protected against siphonage and backpressure by a
vent pipe
1002.1
Of those listed, storm drain systems shall be tested upon completion of the rough piping by using
10 foot head of water
1106.2.1
A water supply to a urinal shall be protected by an approved...
vacuum breaker 412.2
A water heater installed in a residential garage shall be
located or protected from damage by a moving vehicle
507.13.1
A 2-inch vent pipe will serve a total of
24 lavatories
904.1
Tables 702.1 & 703.2
interceptors for sand and similar heavy solids shall have a water seat or not less than
6 inches
1009.3
Storm water shall not be drained into sewers intended for
sanitary drainage only
1101.3
Automatically controlled flushometer valves may be substituted for
flush tanks 413.2
Water heaters of other than the direct-vent type shall be located
as close as practical to the chimney or gas vent
504.2
The minimum size vent pipe that may serve a 4-inch trap is
2 inches
904.1
Each fixture discharging into a gravity grease interceptor shall be
individually trapped and vented
1014.1.1
All rainwater sumps serving ”public use” occupancy buildings shall be provided with
dual pumps
1101.14
The clear space in front of any water closet or bidet shall not be less than
24 inches 402.5
Water heaters supported from the ground shall rest on
a level concrete or other approved base
507.4
A horizontal wet vent shall be not less than two inches in diameter for_____dfu or less
4
908.2.2
Sand and similar interceptors shall have a water seal of not less than___ inches.
6
1016.4
Roof areas of 10,000 square feet or less shall have no less than (controlled flow roof drainage)
two drains
11052.1(3)
Overflows shall be installed in accordance with what section?
Section 404.1
Where exhaust fans, clothes dryers, and kitchen ventilation systems interfere with the operation of appliances, what shall be provided?
Makeup Air 506.1.3
The design and sizing of a vent system shall be permitted to be determined by.....
accepted engineering practices
912.1
A ____ shall be installed downstream of hydromechanical grease interceptors in accordance with the requirements of this code.
Vent
1014.2.2
Cleanouts for building storm drains shall comply with the requirements of Section ____ of this code.
719.0
1101.13