Chapter 4
Chapter 5
Chapter 9
Chapter 10
Chapter 11
100

Screws or bolts for securing floor-mounted fixtures shall be?

Copper alloy 402.3

100

The minimum capacity for a storage water heater is

based on the “first hour rating” and the number of bedrooms and bathrooms

501.1 and Table 501.1(1)

100

Under certain conditions, traps serving sinks that are part of the equipment of bars, soda fountains, and counters  

need not be vented

902.2

100

Each plumbing fixture trap shall be protected against siphonage and backpressure by a

vent pipe

1002.1

100

Of those listed, storm drain systems shall be tested upon completion of the rough piping by using

10 foot head of water

1106.2.1

200

A water supply to a urinal shall be protected by an approved...

vacuum breaker 412.2

200

A water heater installed in a residential garage shall be

located or protected from damage by a moving vehicle

507.13.1

200

A 2-inch vent pipe will serve a total of  

24 lavatories

904.1

Tables 702.1 & 703.2

200

interceptors for sand and similar heavy solids shall have a water seat or not less than  

6 inches

1009.3

200

Storm water shall not be drained into sewers intended for  

sanitary drainage only

1101.3

300

Automatically controlled flushometer valves may be substituted for

flush tanks 413.2

300

Water heaters of other than the direct-vent type shall be located

as close as practical to the chimney or gas vent

504.2

300

The minimum size vent pipe that may serve a 4-inch trap is  

2 inches

904.1

300

Each fixture discharging into a gravity grease interceptor shall be  

individually trapped and vented

1014.1.1

300

All rainwater sumps serving ”public use” occupancy buildings shall be provided with

dual pumps

1101.14

400

The clear space in front of any water closet or bidet shall not be less than

24 inches 402.5

400

Water heaters supported from the ground shall rest on

a level concrete or other approved base

507.4

400

A horizontal wet vent shall be not less than two inches in diameter for_____dfu or less

4

908.2.2

400

Sand and similar interceptors shall have a water seal of not less than___ inches.

6

1016.4

400

Roof areas of 10,000 square feet or less shall have no less than (controlled flow roof drainage)  

two drains

11052.1(3)

500

Overflows shall be installed in accordance with what section?

Section 404.1 

500

Where exhaust fans, clothes dryers, and kitchen ventilation systems interfere with the operation of appliances, what shall be provided?

Makeup Air 506.1.3

500

The design and sizing of a vent system shall be permitted to be determined by.....

accepted engineering practices

912.1

500

A ____ shall be installed downstream of hydromechanical grease interceptors in accordance with the requirements of this code.

Vent 

1014.2.2

500

Cleanouts for building storm drains shall comply with the requirements of Section ____ of this code.

719.0

1101.13