Chapter 6
Chapter 7
Chapter 8
Chapter 12
CH. 6,7,8 12 review
100

What is the primary reason for installing backflow prevention assemblies?

To prevent pollution or contamination of the potable water supply

100

What is the maximum fixture unit loading allowed on a 2 inch waste stack is?

16

100

The developed length from the fixture outlet of a bar sink to the receptor shall not exceed____ feet

5

100

Horizontal 1/2 inch diameter steel fuel gas piping shall be supported at intervals not exceeding____feet

6

100

In what chapter does it talk about water supply?

Ch. 6

200

The duration for a water system pressure test shall be for a period of not less than

15 minutes

200

Cleanouts shall be designed to be

gastight and watertight

200

A standpipe for a clothes washer shall have a minimum and maximum length of?

18 inches to 30 inches

200

Concealed gas piping shall not be located in ?

Solid partitions

200

What section in Ch. 8 does it say "Female plastic screwed fittings shall be used with plastic male fittings and plastic threads"?

814.7

300

All backflow devices or assemblies shaft be tested by a ?

certified backflow assembly tester

300

A straight run of building sewer will require cleanouts at intervals not to exceed what?

100 feet

300

An indirect waste receptor shall not be installed in a?

Toilet room

300

When a flanged joint is opened, the gasket shall be?

Replaced

300

In Ch. 7 how many fixture units does a public water closet, greater than 1.6 GPF gravity tank have?

6

400

Water piping may be installed in the same trench with less than 12 inches of separation from a building sewer constructed of ?

cast iron

400

The minimum size discharge pipe from an ejector or pump in a single dwelling unit having a water closet connected thereto is?

2 inches

400

Water having a temperature above____     shall not be discharged under pressure directly into the drainage system.

140° F

400

Liquefied petroleum gas facilities shall comply with?

NFPA 58

400

What is the approximate gas input for a 50 gallon water heater?

50,000

500

Where potable water is discharged to the drainage system, it shall be by means of an approved air gap of two pipe diameters of the supply inlet, but in no case shall the gap be less than ____?

1 inch 

(603.4.4)

500

What is the drainage fixture unit of a 2 inch trap and trap arm?

4  units 

(table 702.2(1)

500

Indirect waste pipes exceeding ____ feet, but less than ____ feet in length shall be directly trapped, but such traps need not be vented.

5 feet, 15 feet

500

Pressure regulators shall be protected against?

physical damage

500

What is the maximum drainage fixture units of a 4 inch trap and trap arm?

8 units