Fall Protection
AWP & Ladders
Hazcom & PPE
Signalman & Rigging
Forklift Safety
Fire/Electrical & Heat Safety
100

The minimum height above a lower level that requires fall protection.

What is 6 feet

100


When using a boom-type lift, workers must wear this type of protection.

What is a fully body harness and lanyard. 

100

Employers must maintain these documents for each chemical used on site.

What are Safety Data Sheets (SDS)

100

When hoisting materials to the roof, loads must be properly balanced and controlled by this qualified worker.

Who is the Signal Person

100

The minimum amount of fire extinguishers required on production projects. 

What is 2, 10lb, ABC 

200

The maximum roof slope where a safety monitor system can be used alone.

What is 2:12

200

This is prohibited inside an aerial lift basket.

What is using planks or ladders to gain extra height

200

Workers must be trained on chemical hazards before they start work under this program.

What is the Hazard Communication Program (HazCom)

200

Forklift operators must be trained and evaluated at least this often.

What is every 3 years

200

Roofing torches and hot-work operations must have a fire watch for at least this long after work stops.

What is 30 minutes

300

A safety monitoring system alone may not be used on roofs wider than this.

What is 50 feet

300

The correct ladder setup angle is this ratio of height to base distance.

What is 4:1

300

PPE must be provided at this cost to the employee.

What is no cost (free)

300


Using a forklift to lift workers is only allowed if this safety feature is present.

What is a properly designed work platform approved by the manufacturer

300

Centimark’s heat rule applies when the heat index reaches this temperature.

What is 80°F

400


OSHA has made efforts to protect workers working at high heights by reducing fall-protection trigger height from 10 ft to this.

What is 6 feet

400


Before each use, the operator must check aerial work platforms for these 3 items.

What are leaks, mechanical defects, and guardrail condition

400

Name one common PPE required for roofing work.

What is eye protection, hard hat, or non-slip footwear

400

The most common forklift hazard when driving on slopes or with raised loads.

What is tip-over

400

Centimark’s heat rule requires additional water, shade, and rest breaks starting at this temperature.

What is 90°F

500

On low-slope roofs, the competent person responsible for observing and warning workers under a safety monitoring system is called this.

Who is the Safety Monitor

500

When moving an aerial lift or ladder near electrical lines, the minimum safe clearance is this many feet.

What is 10 feet

500

Centimark's PPE rule requires that defective equipment be removed from service immediately by this person.

Who is the supervisor or competent person?

500

Rigging and lifting devices must be inspected before each use by this person.

Who is a Competent Person

500

When working near live electrical wires, workers must stay at least this many feet away unless lines are de-energized.

What is 10 feet