Oops... Now What?
Red Flags in the OR
See Something, Say Something
Count on Me!
OR Wizard
100

You accidentally contaminate your sterile glove while setting up the back table. What should you do?

Immediately stop, acknowledge the contamination, and change your glove before continuing.

100


Is this indicator showing sterile or nonsterile?

non sterile

100

A circulator reaches across the sterile back table to grab a specimen. What should happen?

Tell the circulator they cannot reach over the sterile field.  the area they reached over is considered contaminated.

100

During closing counts, you and the circulator discover that the sponge count is incorrect. The surgeon wants to continue closing. What should you do?

Immediately communicate the discrepancy-go through notification process (nurse, surgeon, code rust)

100

An instrument tray is open and after grabbing the tray you notice water on the bottom. What are your next steps?

do not put tray on your table.(if set on the table must be replaced)

remove gloves (and gown if it was touched), replace tray

200

Your needle count is incorrect. You search the field, floor, trash, and surrounding area.  What is the next Step? 

Code Rust

200

You notice the surgeon's gown has become contaminated. You speak up, but the surgeon says, "I've already made contact with the patient. Changing now won't make a difference."

Question: If contamination has already occurred, why does correcting it still matter? What steps should be done to correct the contamination?

Further contamination can still be prevented. Their glove should be changed and anything they touched should be replaced. Antibiotic maybe prescribed to protect the patient since.

200

Every count is correct, but you personally witnessed a sponge fall into the patient's abdominal cavity and cannot remember seeing it removed. What do you do?

Speak up and ask for a recount.  mention it to the surgeon to see if they can double check in the abdominal cavity.  have them verify they took the sponge out.

200

After a code rust who can give/recieve the final report?

radiologist to head physician in the room.

200

Sterile or Not Sterile- If not sterile what is wrong?


Sterile

300

Your surgeon places the drape then decides they need to move it.  What are the next steps?

remove the drape, patient needs reprepped with a new dry time, change of gown and gloves as needed, replace with a new drape.  

300

How often should you wash your cloth scrub cap? (Per Cleveland Clinic Policy)

after each use

300

You are scrubbed into a case as an intern and you preceptor said they are going to break super fast to run to the bathroom.  How do you respond?

Ask for someone else to come and scrub in with you.  As an intern you are not able to be scrubbed in alone with the patient in the room. 

300

per Cleveland clinic policy

How many lap sponges can be left on the table after the final count?

5

300

What are the names of the different types of counts done throughout surgery.

initial

closing

final

reconcile

400

There is a code blue and the Zoll has a bunch of cords around it.  Which cord do the Zoll pads get plugged into?


point to cord

400

A sterile peel-pack item is dropped onto the floor immediately before the case. The package appears completely intact. What should you do?

the item is considered compromised

400

Your final count is incorrect. The circulator says they remember seeing the missing sponge earlier, and the surgeon says they are confident everything is out. 

Who is responsible for speaking up, and what steps should happen next if they want to continue closing?

you are responsible to speak up.  if the circulator and surgeon do not want to stop you need to notify the nurse manager or charge nurse.

400

A clamp breaks, and you recover the handle but cannot locate the tip. The surgeon says the missing piece is probably in the instrument tray. What do you do?

notify the circulator. Call for a code rust

400

Your preceptor makes a mistake during setup. You recognize it, but they tell you not to worry about it because they have been doing this for 20 years. You are only three weeks into your internship.

How do you respectfully challenge someone with more experience than you?

Use clear, respectful language such as, "I may be missing something, but I noticed..." Explain the specific safety concern and request clarification. If the issue remains unresolved, escalate through the appropriate chain of command. Experience does not replace safety standards.

500

A medication is handed to you in a sterile cup. You recognize the color of the liquid but cannot verify its identity. The surgeon says, "I've used this all day. Just pass it."

What is the biggest safety issue, and what should you do?

Color and familiarity are not medication identification. Do not pass an unidentified medication for use. Stop, communicate the concern, and have the medication identified and verified through the required process before it is used.  if it cannot be verified throw it away and get new.

500

You realize that two specimens may have been switched. Both are already labeled, and one has left the operating room.

Question: What is your immediate responsibility? What if correcting the mistake delays a cancer diagnosis?

Immediate responsibility would be to notify your team that there might have been a switch, call the lab and have surgeon identify which specimen is which.

Correcting the mistake delays a cancer diagnosis but make sure the patient is getting the correct diagnosis. 

500

The patient becomes unstable, and the surgeon needs to close immediately. You have not preformed a final count

Question: Do you ignore the count discrepancy because the patient is unstable?

No. Immediately communicate the discrepancy. Patient stabilization takes priority in an emergency, but the team must follow the emergency count discrepancy protocol, including appropriate searching, imaging when indicated, and documentation.

500

How many pieces are in a standard Book Walter set?

Standard-20

complete or bariatric set- 26-31 

500

describe the table breakdown process

wipe down instruments using sterile water

  • Remove any sharps using instrumentation or safety scalpel remover and dispose in sharps bin

    How to breakdown your instruments for transport:

    • Any instrument trays opened in the OR are required to be treated as contaminated. 

    • Remove paper and indicators from all instrument trays.

    •  Identify broken or malfunctioning instruments and place in appropriate transportation container.

    • Place heavy instruments on bottom of tray.
      Open box locks (hinged instruments) and stack neatly together with curved tips pointing down.

    • Flush all instruments with lumens with sterile water.

    • Separate sharp, glass, and delicate instruments and place visibly on top inside instrument tray.

    • A towel may be used to separate items within a tray.