Definitions
General Requirements
MORE General Requirements
Safe Use
Fall Protection and Falling Object Protection
100

One who is capable of identifying…hazards in the surroundings …and who has authorization to take prompt corrective measures to eliminate them.

Competent Person

100

Scaffolds and their components need to be able to withstand ____ times the maximum intended load

4

1926.451(a)(1)

100

Front edge of all platforms shall not be more than ____” from the face of the work, unless guardrail systems are erected along the front edge or PFAS is used (with exceptions)

14”

1926.451(b)(3)

100

Scaffolds & components shall be inspected for visible defects after any occurrence that could affect the structural integrity AND _________

Before each work shift

1926.451(f)(3)

100

Guardrail systems shall be installed along all ____ ____ and ____ of platforms

Open sides/ends

1926.451(g)(4)(i)

200

Device that locks together the tubes of a tube & coupler scaffold

Coupler

200

Scaffolds shall be designed by a _____ person

Qualified

1926.451 (a)(6)

200

End of a platform, 10’ or less, shall not extend over its support more than ___”

12”

Unless the platform is designed/installed so the cantilevered portion of the platform is able to support employees/materials w/o tipping OR has guardrails blocking employee access to the cantilevered end

1926.451(b)(5)(i)

*OVER 10’ in length, do not extend more than 18” over supports

200

Clearance between the scaffold and uninsulated <50kv powerlines must be a minimum of ___’ unless de-energized or otherwise approved by the power company

10’

1926.451(f)(6) (table)

200

Each employee on a scaffold more than ___’ above a lower level shall be protected from falling to that lower level


10’

1926.451(g)(1)

300

Structural member…used to increase the base width of a scaffold in order to provide support for and increased stability

Outrigger

300

Each platform on every level shall be _____ _____ or decked between the front uprights and the guardrail supports

Fully Planked

1926.451(b)(1)

300

Wood platforms shall not be covered with _____ _____, except…edges may be covered or marked for identification

opaque finish

1926.451(b)(9)

May periodically coat w/wood preservatives, fire retardant finishes, slip-resistant finishes, but must not obscure the top/bottom of the wood surface

300

Employees shall be prohibited from working on scaffolds covered in ___, ___, or other ___ ___ except as necessary for removal of such materials

Snow/ice/slippery material

1926.451(f)(8)

300

Approved forms of fall protection include _____ or _______ systems

PFAS/guardrail

(safety nets are not often used on scaffolds for fall arrest, but CAN be)

1926.451(g)(1)(vii)

400

Work surface elevated above lower levels…constructed using individual wood planks, fabricated planks, fabricated decks…

Platform

400

On each platform the space between adjacent planks/decks/platforms shall not exceed ____”

1”

1926.451(b)(1)(i)

400

Supported scaffolds with a height to base width ratio of more than _____ shall be restrained from tipping by guying, tying, bracing, etc

4:1

1926.451(c)(1)

400

___ shall not be used on a scaffold to increase ones working height (w/some very specific exceptions)

Ladders

1925.451(f)(15)

400

Along with hardhats, each employee shall be provided ____, screens, guardrails, debris ___, etc to protect them against falling objects

Toeboards/nets

1926.451(h)(1)

500

Portion of a scaffold platform used only for access and not as a work level

Walkway

500

Each platform and walkway shall be at least ____” wide (with a couple exceptions)

18

1926.451(b)(2)

500

Supported scaffold poles, legs, posts, frames & uprights shall bear on ___ ___ and ___ ___ or other adequate firm foundation

Base plates/mud sills

1926.451(c)(2)

500

Work from scaffolds is ___ during storms or high winds

Prohibited

1926.451(f)(12)

Unless deemed safe by Competent Person AND FP is provided

500

Toeboards shall be at least ___” high from the top edge of the toeboard to the level of the walking/working surface

3.5”

1926.451(h)(4)(ii)