Meter Clearances Residential,
Rooftops & Inside
Hazardous Conditions & Meter Guards
Flood Areas & Historic Districts
Internal/External Relief Valves & Vent Lines Terminations
Meter & Regulator Locations
100

Residential meters shall not be connected to __________ piping downstream of the meter? 

Underground.

100

Meter should be located on the _________ wall?

Front.

100

Meters & Regulators known to flood should be located above the ___________ _______ ______?

High Water Mark?

100

Flow from the Vent is turned ____________ to prevent rain water into the vent?

Downward.

100

__________ & __________ ________ are installed in high pressure systems near the point of delivery of gas to the customer?

Meters & Service Regulators.

200

Residential meters maintain a minimum distance of __________ foot from arc producing electrical equipment?

1 foot.

200

Install meters & regulators away from ___________,___________,_________,__________ hazards whenever practical?

Roads, Driveways, Parking Areas & Traffic.

200

In historical building it may be necessary to locate meters in __________ with the historical character of the building?

Harmony.

200

When an underground route is not practical the vent may only be installed __________?

Underground?

200

Service Regulators are not needed when gas is delivered from _____________ pressure systems?

Low.

300

Rooftop meters maintain a minimum of _____ feet from the meter to the edge of a roof unprotected drop off?

6 Feet.

300

If additional protection is required contact __________ ________?

Corporate Engineering.

300

The regulator vent should terminate _______ inches above the High Water mark in areas known to flood?

12 inches.

300

Each relief valve vent & each internal relief valve vent must have its own _________ vent line?

Separate.

300

Meters measure the __________ of pressure? 

Volume.

400

This __________ meter should maintain a minimum distance of 3 feet from sources of heat that could raise the temperature of the meter to 120 degrees Fahrenheit or otherwise damage the meter? 

Inside Meters.

400

Guards may consist of but are not limited to ___________,______,______ etc?

Posts, Bollards & Railings

400

__________ __________ are installed to protect the Meter and Regulators?

Meter Guards?

400

Allow gas to vent freely away from building openings such as _________,________, or air intakes?

Windows & Doors.

400

_____________ _______________ reduce & control the delivery pressure?

Service Regulators.

500

Meters must ensure adequate clearance & accessibility for meter __________, ____________ & ____________?

Reading, Maintenance & Operation.

500

Damages to facilities installed outside or inside of structures are due to:

Component Failure, 3rd party damage, Natural disaster or human error can create a hazardous condition.

500

On all New Business projects the installation of vent lines __________ shall be the preferred method?

Aboveground.

500

When selecting a location WG field operations must be aware of?

1. ____________

2. ____________

3. ____________

Potential Ignition Sources

Potential Heat Sources

Vehicular & Pedestrian traffic

600

Rooftop meters must maintain a minimum of _____feet from the edge of a roof where a rigidly fixed guards or rails where fixed? 

3 Feet.

600

All Vent terminations shall terminate outdoors at least ______ inches above grade with an ___________ resistant screen.

12 inches 

Insect


700

Meters & Regulators should not be located on ___________ or __________ buildings?

Rooftops or Inside Buildings.

700

The flow to a relief vent should not be shutoff unless the gas supply to the ___________ has been shut off?

Regulator.

800

Residential meters maintain a minimum of _____ feet from fan induced ventilation air intakes to a buildings?

10 feet.

800

This ______ _____ valve is built into a regulator?

Internal Relief.

900

An ___________ door is not to be considered a vent?

Undercut.

900

Vent lines terminate above the High water mark in areas known to flood. If not known terminate above the __________ year flood level?

100.

1000

Inside meters may only be installed in a ___________ space?

Ventilated.