ALPHA
BETA
CHARLIE
DELTA
ECHO
100

It is when only muscle and fat are imaged.

Soft Tissue Radiography

100

_____ ________ of breast cancer leads to more effective treatment and fewer deaths.

Early detection

100

The x-ray beam intensity near the cathode side of the x-ray tube is significantly higher than that on the anode side due to the heel effect.

Heel Effect

100

This is one important consideration in the overall efficacy of mammography.

Patient radiation dose

100

These are used routinely to reduce scatter radiation and improve image contrast while maintaining spatial resolution. 

Grids

200

The second leading cause of death from cancer in women.

Breast Cancer

200

For symptomatic or high-risk patients, often requiring more views.

Diagnostic Mammography

200

The radiographic examination of the breast. 

Mammography

200

It detects cancer in asymptomatic women using two views.

Screening Mammography

200

Most cases of breast cancer occur in the _________________ of the breast.

Upper Outer Quadrant

300

Spatial resolution and contrast resolution were much improved because of this.

Edge Enhancement.

300

These measure x-ray intensity and x-ray quality at the image receptor.

Phototimers or AEC devices

300

This set standards for image quality, patient radiation dose, personnel qualifications, and examination procedures.

Mammography Quality Standards Act (MQSA)

300

GdOS stands for?

Gadolinium Oxysulfide

300

This allows for lesser OID for better spatial resolution, uniform thickness of breast, and lower patient dose.



Compression

400

This rovides 3D imaging by taking multiple images at different angles while keeping the breast still.

Digital Mammographic Tomosynthesis (DMT)

400

The two types of filtration.

Added and Inherent

400

Breast tissue consists of these tissues.

Fibrous, Glandular, Adipose

400

Screen-film mammography uses what materials to enhance image quality?

Rare Earth Screen

400

The three main target materials

Tungsten, Molybdenum, Rhodium

500

In the 1960s, Wolf and Ruzicka showed that __________________ was superior to direct film exposure at a much lower patient radiation dose.

Xeromammography

500

Lower kVp improves visibility but requires _______ ____, increasing radiation exposure.

Higher mAs

500

The year x-ray mammography became clinically acceptable using molybdenum target.

1966

500

A principle to achieve the small effective focal spot.

Line Focus Principle

500

Large focal spot size is ____ mm.

0.3