EMT shall be securely fastened in place at least every ____ feet.

10 feet

100

Lengths of busway are allowed to extend through _____  if they are unbroken. 

Dry walls.

100

How far must the separation be between any light, power, or Class 1 conductors or radio and television conductors, and underground antenna conductors for radio and television receiving equipment. 

12 in

100

For a fixed or stationary electric sign installed in a fountain, the disconnecting means must be at least how far horizontally from the inside wall of the fountain?

5 ft

100

Essential electrical systems for hospitals are comprised of which branches?

The life safety, equipment, and the critical

200

Three-way and four-way switches shall be so wired that all switching is done:

Only in the underground circuit conductor.

200

Conductors, including splices and taps, shall not fill gutters to more than ____ percent of its area.

75%

200
Unless otherwise permitted, communications cables and wires must be separated at least 2 in. from what circuit conductors?

Power, lighting, or Class 1

200

From the inside walls of an indoor installed spa or hot tub to the wall switches, what is the minimum distance?

5 feet

200

What is the minimum rating allowed for 120/240 volt, single-phase service equipment for a mobile home?

100 amperes

300

Fixtures shall not be smaller than _____ AWG.

18

300

For a 4-inch square box 2.125" deep, with No. 12 copper conductors, what is the maximum fill allowance?

13

300

What is the minimum clearance for communications wires and cables above all points of roofs above which they pass?

8 feet

300

What is the smallest size grounding conductor allowed for grounding the structural reinforcing steel of a swimming pool?

8 AWG

300

What is the minimum rating for single receptacle shore power for boats?

30 amperes

400
A No. 14 fixture wire has an allowable ampacity of: 

17

400

The volume allowance required for each 14 AWG conductor, when calculating box fill, shall be ______ cubic inches.

2 cubic inches

400

A bonding jumper not smaller than ____ AWG copper or equivalent must be connected between the radio and tv equipment grounding electrode and the power grounding electrode system when they are separate. 

6 AWG

400

The term for the circuit(s) between modules and from modules in a PV system to the common connection point(s) of the direct-current system is:

Photovoltaic source circuit

400

Which Class locations is hazardous because of the presence of materials producing combustible flyings, or having easily ignitable fibers present, but where they are not expected to be in sufficient quantities to create an ignitable mixture?

Class III

500

Where may flexible cords and cables not be used?

When run through holes in walls.

500

All metal boxes shall be _____ or bonded. 

Grounded

500

True or False: The raceway fill limitations detailed in 300.17 will apply to coaxial cables. 

False

500

What is the minimum percentage of the maximum current rating for PV system overcurrent devices, as calculated in 690.8(A)?

125%

500

True or false: Receptacles in health care facilities that have isolated grounding terminals as described in 250.146(D) are allowed in the vicinity of patient care areas.

False