100

NEC table used to size an equipment grounding conductor 

What is table 250.122

100

The ampere rating of a circuit breaker is located here 

What is the handle of the device 

100

Name the type of fuse shown * Show Fuse*

What is Edison-based 

100

Name two of the three basic types of three-phase motors 

What is squirrel-cage induction, wound-rotor induction, synchronous motor

100

Where the midpoint of one phase winding is grounded on a 4-wire delta-connected system the higher phase voltage to ground shall be durably and permanently marked by this color ____

What is orange


110.15 

200

The continuity between service equipment and enclosures is maintained by _____

What is bonding 

200
A Class _____ device will trip when fault current to ground is 6mA or more 

What is class A 

200

Name any two of the five markings that are required to be attached on a cartridge type fuse 

What is Ampere rating, voltage rating, interrupting rating, current limiting, name or trade mark

200

When connecting a Wye OR Delta motor in a high-voltage application, the motor windings would be connected in _____

What is series 

200

The FLC for a polyphase 50Hp synchronous-type motor operating at 480v 

What is 52amps 


T430.250

300

When connected to a rod, pipe, or plate electrode, the minimum size grounding electrode conductor required for a 320amp residential service is  

What is #6 AWG

300

Name one of the two organizations that test and list overcurrent devices as safe to use

What is UL or CSA (Canadian Standards Association)

300

The term _____ is used when determining the time-current relationship among overcurrent protective devices connected in series 

What is coordination 

300

Name two methods used to determine the rotating direction of a three-phase motor 

What is bump the motor, phase rotation meter 

300

Conduit or tubing not exceeding ____ in length can be filled to ____ % of their total cross-sectional area 

What is 24" and 60% 

Chapter 9 table 1 note #4

400

Name one of the three types of bonding jumpers that are permitted by the code 

What is Wire, bus, screw 

400

Frame size for molded-case circuit breakers are identified by the _____ ampere rating available 

What is largest 

400

Single-element fuses respond quickly to this type of circuit

What is short circuit 

400

The difference between the speed of the rotating magnetic field and the actual rotor speed in an induction type motor is called ____

What is slip

400

Isolated power systems (often used in health care facilities) shall have circuit conductors identified by 

What is orange and brown with distinctive strip other than white, green, or gray

500

The minimum size wire type bonding jumper required for a 3000A service fed with 10 parallel runs of 350kCIML 

What is 500kCMIL

Table 250.102(C)(1) Note #1 

350,000 X 10 = 3,5000,000 x .125= 437,500 round up to 500 kCMIL

500

In residential applications, the available fault current is rarely higher than _____

What is 10,000 Amps 

500

When sizing fuses for a given application, having a _____ of the system is essential 

What is schematic 

500

What is the electrical equivalent in watts of 1 horsepower of mechanical energy 

What is 746 
500

Where the rating from table 430.52(C)(1) is not sufficient for starting current of a motor, an inverse time circuit breaker can be increased to a maximum of ____ % of the FLC when  _____ amperes or less. 

What is 400% and 100amps 


430.52(C)(1)(3)