Filters
Power Factor
Three-Phase Systems
Transformers and Motors
Test Instruments
100

This filter allows low frequencies to pass while blocking high frequencies.

What is a low-pass filter?

100

Power factor is the ratio of this type of power to apparent power.

What is true power?

100

To find phase voltage in a wye system, divide the line voltage by this number.

What is 1.732 (√3)?

100

The primary function of a transformer is to perform this task.

What is step up or step down voltage?

100

This instrument measures current without opening the circuit.

What is a clamp-on ammeter?

200

This filter allows high-frequency signals to pass while blocking low-frequency signals.

What is a high-pass filter?

200

A power factor of 1.0 means all supplied power is converted into this.

What is useful work (real power)?

200

In a delta system, line voltage has this relationship to phase voltage.

What is line voltage equals phase voltage?

200

The voltage ratio of a transformer depends on this.

What is the number of turns in the primary and secondary windings?

200

This instrument measures voltage, current, and resistance in one device.

What is a multimeter?

300

This filter is commonly used in audio applications to isolate mid-range frequencies.

What is a band-pass filter?

300

This type of load usually causes a lagging power factor.

What is an inductive load?

300

This type of three-phase connection provides both line-to-line and line-to-neutral voltages.

What is a wye connection?

300

When connecting transformers in parallel, this value must be the same.

What is percent impedance (%Z)?

300

This instrument checks for voltage without making direct contact with a live conductor.

What is a voltage indicator?

400

This filter blocks a narrow range of frequencies while allowing most others to pass.

What is a band-reject filter?

400

This component is commonly installed in parallel with an inductive load to improve power factor.

What is a capacitor?

400

Industrial facilities often use this connection because it does not require a neutral conductor.

What is a delta connection?

400

Compared to single-phase motors, this type of motor operates more smoothly and efficiently.

What is a three-phase motor?

400

This instrument is used to test the insulation resistance of motors and cables.

What is a megohmmeter?

500

This point on a filter's response curve is the frequency at which the load receives 50% of its maximum power.

What is the half-power point?

500

Power factor is usually corrected to about 90–95% to avoid this condition.

What is a leading power factor (overcorrection)?

500

In a 4-wire delta system, this conductor has a voltage to ground equal to 1.732 times the phase voltage.

What is the high leg (wild leg)?

500

A motor experiencing single-phasing will most likely exhibit this symptom.

What is overheating and possible stalling under load?

500

Before connecting an in-line ammeter, this must be done first.

What is de-energize the circuit?