100

The difference between system overshoot and system lag.

temperature swing

100

Used to prove that the combustion blower motor is operating before ignition.

sail switch

100

It's the measurement of current.

amps

100

What high pressure control contacts are normally.

closed

100

The ability to reduce the flow of electrons.

resistance

200

Rapid making and breaking of a contact.

detent

200

It's how the cold anticipator is wired with the mercury bulb cooling contacts and is energized during the off cycle.

parallel

200

The net oil pressure of a system where the suction pressure is 60 psig and the oil pump outlet is 85 psig

25 psig

200

It's used to describe when the temperature of a heated room falls below the thermostat's set point

system lag

200

It's used in some applications to sense temperature in a moving air stream.

helix coil

300

It's when the heat anticipator in the thermostat control circuit in the heating mode is active

when the heating contact is closed

300

When the heater in the thermostat control circuit in the cooling mode is active

when the cooling contact is open

300

The proper setting to turn on a system at 28 psig and shut down at 2 psig

High event: 28 psig, differential: 26 psig

300

Its attached to a large diaphragm to control ice build-up on a heat pump outdoor coil in the heating cycle.

micro-switch

300

A group of thermocouples wired in series with each other to provide a higher output voltage

thermopile

400

They must determine what the current flow is through the heating control circuit when the furnace is operating in a steady state condition.

heating technician

400

It's how to obtain an accurate reading of a fluid in a large pipe

use a permanently mounted thermometer in a well

400

Measures the difference in pressure to establish that positive oil pressure is present.

oil pressure safety controls

400

Where a water regulating valve that is controlling head pressure is installed.

water circuit at the inlet of condenser

400

It's used to describe when the temperature of a heated room rises above the thermostat's set point

system overshoot

500

Sensing elements used in line voltage thermostats with heavier contacts.

bimetal, bellows, and remote bulb

500

The manifold pressure of many natural gas fired heating units 

3.5 in 

500

It's why two different metals are used to produce movement in bimetal elements.

when metals expand and contract at different rates as temperature changes

500

Starts the cooling system early to allow the air-conditioning system to get up to capacity when needed.

cold anticipator

500

A battery produces 12.6 volts what would be the current flow for a 6 Ohm resistor?

2.1 amps