Yellow
Green
Blue
Purple
Red
100

The digester is feed by which process?

 Gravity Thickener

100

What is the capacity of digester 3?

315,900 gallons

100

What is the formula for volatile solids reduction?

In – Out / In – (In x Out) x 100

100

How many diffusers are in digester 2?

72

100

 What is the minimum SRT and temp we can have in the digester?

16 days @ 26c

200

What class of sludge does our digester produce?

Class B

200

What horsepower are digester blowers 1 2 & 3?

54 hp

200

Are the air diffusers in the digesters fine or coarse bubble diffusers?

Coarse Bubble

200

How many diffusers are in digester 3?

96

200

How many gallons are in a foot for digester 3?

15,867 gallons

300

What does VSR stand for?

Volatile Solids Reduction

300

What horsepower are digester blowers 4 & 5?

125 hp

300

Calculate the VSR: In volatile solids 80%, Out volatile solids 70%?

42% VSR

300

Which PLC controls digester blowers 1 – 3?

PLC 1

300

What is the target solids concentration of digester 3?

1.5% - 2.0%

400

What is the minimum VSR we can have from the digester?

38%

400

What is the CFM output of digester blowers 4 & 5?

1650 CFM

400

What pressure are the pressure relief valves on digester blowers 4 & 5 set to release at?

 11 psi

400

Which PLC controls digester blowers 4 & 5?  

PLC 4

400

What is the number 1 cause of foaming in an aerobic digester?

High organic loading

500

What is the capacity of digesters 1 & 2 (each)?

236,900 gallons

500

What is the pump capacity of the old digester pumps?

120 gpm

500

How many diffusers are in digester 1?

120

500

What is the current SRT of our digester?

38 days

500

What is the target volatile solids percent in the digester?

70% or less