Defensive Driving
FVD, Conductive Cap and W1BU Cord
Temporary Bonds
Insulating Gloves
Asbestos
100

Checking mirrors, glass, tires, lights, horn, and wipers are all part of this important part of safety.

What is the daily vehicle inspection?

100

The voltage indicator (red bar graph) will step rapidly upward and the alarm will sound at this many volts when the (sixth) red bar illuminates.

What is 50-volts?

100
When testing your bonds with the JDSU (copper meter) your ohms reading should be this

What is 1 ohm or less?

100

Each rubber insulating glove sleeve or cuff is labeled in color denoting this and this.

What are class rating and maximum use voltage?

100

Goggles, gloves, and dust mask are all examples of this

What is PPE?

200

Areas that are not visible in your mirrors or with your peripheral vision

What are blind spots?

200
The FVD has this many LED lights on the face.

What is 11?

200

The small clamp goes to this while the large clamp goes to this.

What is ground and object?

200

Rubber insulating gloves must be this when received, before and after each use, and when damage is suspected.

What is when to inspect insulating rubber glove?

200

Before beginning the work make sure the immediate area is clear of blank

What are untrained persons/people?

300

Driving, Drowsy, Distracted make up the blank of unsafe driving.

What are the 3D's of unsafe driving?
300

The test plug that is used to test the FVD functionality when we receive it and once a month

What is a 193A test plug?

300

No temporary bond should be placed without wearing these.

What are insulating gloves?

300

1. Cut each glove on palm side of the glove, from the gauntlet to the finger. 2. Dispose in normal trash.

What is how to dispose of defective rubber gloves?

300

If suspect materials are found, slowly lower the end of the this back into the framework and contact your manager or building owner (per local instructions).

What is a ceiling tile?

400

Eye Lead Time, Constant Eye Movement, Mirror Checks, and Head Checks are all part of this technique.

What is the Four-Search technique?

400

These special pieces of safety equipment are used to verify if induction is present with the FVD

What are the W1BU cord and conductive cap? 

400

Acceptable ground sources for a temporary bond (there are 3).

What are cable suspension strand, MGN, or power ground at the premise?

400

Placing temporary bonds; driving ground rods; or placing or removing strand, wire, or drop wire near power.

What is when you should wear your insulating gloves?

400

This organization is responsible for developing and enforcing regulations necessary to protect the general public from exposure to chemicals known to be hazardous to human health.

What is the EPA?

500

Make a series of three right turns.

What is a way to avoid making a left turn?

500

Under some conditions this type of reading may still occur due to the E-field becoming concentrated at the object’s surface, even when using the grounded W1BU cord and conductive cap. If a voltage between 50 and 141 Vac (less than full-scale reading) is detected

What is a false positive?

500

Smoke, smell, and sound are all indicators of this.

What is voltage passing through the bond?
500

1. Inspect outside and inside surfaces 2. Remove all foreign particles embedded in the surface, especially splinters of wood or metal. 3. Check the inner portion for sharp or foreign objects.

What is how to inspect your leather protector gloves?

500

This is the trade name for an exterior building material Portland cement reinforced with asbestos fibers. It is sold as a pre-cast corrugated sheet. This material was widely used on homes as exterior siding from the 1940s through the mid-1950s because of its durability and fire-resistant qualities.

What is Transite siding?