What RS indicates caustic corrosion can be assigned as general or local damage type based on temperature.
What is RS-13
Per this best practice, the Unit level of the hierarchy is intended to be used to create the process or non-process unit/location records in PCMS.
What is BP-29
What color should deadlegs be highlighted on the isometric drawings per P66 useful practices?
What is red
Within PCMS, in which field can the identifier of asset or piping system be found?
What is Equipment ID
One-stop shop for key contacts, guidance documents, and helpful links.
What is AIMI Guidance SharePoint Page
Consequence of failure assessment shall be conducted following API 581
What is M-42-RS-14 / 5.8.1
Under Accountabilities of BP-27, who is required to be informed in the event of an SAP Notification Creation in the Accountabilities Matrix Process?
What is Planners/Schedulers and Operations Manager
Per P66 useful practices, how should injection and mixed points be marked on P&IDs?
What is dashed, red square/rectangle
When circuitizing P&IDs via CAD, what indicates a circuit break?
What is Single blue line
Program designed for sites to celebrate individuals who are making a real difference in support of the AIMI program.
What is AIMI Way To Go!
Lists the following questions:
Have all critical deadlegs been reviewed?
Have all established IP/MP's been reviewed?
Have critical DMW's been reviewed?
What is M-42-RS-13 Appendix D
The specific state of an asset’s In-Service stage of life when the asset is not currently in active operation
What is Idle
Necessitate the update of RBI and Corrosion assessments
What is required to be completed by the vendor, site, and Central Inspection SME's before MS4 submission?
What is MS4/5 Checklist
Provides the AIMI Central Team, Site, and Vendor a guidance document that standardizes the evaluation of meeting readiness prior to the start of each milestone meeting.
What is the guidance document.
The number of years back and inspection date used when multiple inspections for grading are utilized to achieve a thinning damage age reset
What is 10 yrs & the date of the oldest/first inspection.
Has a planned/scheduled replacement on a fixed time interval of 10 years, two turnaround cycles if tied to a processing unit, or inspection every 5 years with replacement at first sign of degradation
What is HDPE Storage Tanks
Work process required for sites to prepare for, review and update key corrosion and operational information inside the Inspection database?
What is revalidation
Fewer leaks, less operational and safety risks, less LPO, higher quality, and more consistent data analysis are all what according to P66?
What is Benefits of AIMI
Initial document for each milestone that serves as the starting point to create one set for what will apply to all equipment groups at the site.
What is Global Implementation Assumptions List.
Per M-42-RS-06, some portions shall be their own circuit due to the nature of different techniques and intervals
What is Buried Piping
Shall not exceed this interval for temperature and thinning inspections at Critical Metallurgy Spec Breaks (CSBs)
What is 5 years
Subdivided into streamlined and complete remodel approaches
What is unit-wide revalidation
For external corrosion, at what max year interval shall over water piping have visual inspections scheduled?
What is 3
Refining documents that provide the guidance on the minimum requirements.
What are Required Standards