100

a decrease in superheat causes the thermostatic expansion valve to begin to

close

100

in the evaporator 

latent heat is transferred from the refrigerated spce to the refrigerant 

100

a sight glass would normally be located

in the liquid line before the metering device

100

a liquid-to-suction heat exchanger is often used to

increase liquid subcooling

100

the flow rate of a TEV used in a r410A systems as compared to r-22 systems is

approximately 15% greater

200

a rise in evaporator pressure causes the automatic expansion valve to begin to

open

200

a liquid line filter drier should be placed between the

condenser and the metering device

200

bubbles in the sight glass could be an indication of

a refrigerant blend with a high temperature glide

200

the oil pressure safety switch is operated by

the difference between crankcase pressure and oil pressure

200

when using an electronic leak detector, the sensor probe

should be moved at approximately 1 inch per second

300

a thermal-electric (solid state) expansion valve is controlled by

NTC thermistor

300

a temperature differential across a filter drier indicates

a restricted filter drier

300

which of the following symptom(s) would be indicative of an oil logged condenser

high discharge line pressure and low liquid line pressure

300

a low pressure cut-off switch is used for

establish a minimum operating pressure in the evaporator

300

moisture in a refrigeration system will cause

compressor failure

400

in a direct expansion (DX) evaporator system, the refrigerant enters the evaporator as

mixture of liquid with some "flash gas"

400

a liquid reciever is used to

store liquid refrigerant

400

which of the following is true of a solenoid valve in a pump down system

it is located after the metering device

it is used instead of a metering device

it is located before the metering device

it is located after the evaporator

it is located before the metering device

400

a partially iced over evaporator can be caused by

an undercharge

400

what type of gauge is used to measure microns?

an electronic vacuum gauge

500
which of the following is the most improtant consideration in the selection of an evaporator coil? match the coil to the

condensing unit and the latent/ sensible loads

500

an accumulator is used to 

prevent liquid refrigerant from reaching the compressor

500

the purpose of an evaporator pressure regulating valve (EPR) is to

prevent evaporator pressure from falling below a set limit

500

_____ can be used for leak detection with ALL high pressure refrigerants

soap bubbles

500

in order to remove as much moisture as possible from a system

triple evacuate the system to 500 microns with a deep vacuum pump

600

water will vaporize at ______ temperature in a 28 HG vacuum

100 degrees

600

before a vapor/compression system is opened for service

the refrigerant must be recovered using approved equipment

600

back seating a two way service valve results in

closed service port with normal system flow

600

when topping of an operating system containing a blended refrigerant

introduce the refrigerant as a liquid into the low side using a throttling valve

600

a partially clogged capillary tube can cause

a starved evaporator