Walls
Elevations
Openings
Reflected Ceilings
Site
100

Identify the galvanized steel stud size and thickness of cement board for a typical fire stop wall in the crawlspace.

92mm 20 gauge steel stud

13mm cement board (both sides)

A2.0

100

Identify the elevation of the glass spandrel on the west elevation between GL A and GL D

Elevation 108 300

A4.1

100

Identify the room name and room number for the crawlspace floor access hatch with a ladder.

Mechanical 

1:111

A2.1

100

Identify the type and height of ceiling in room 1:100.

GB @ 2400mm

A3.1

100

Identify the design grade at the main entrance.

El. 230.950 M

A1.1

200

Identify the wall type(s) and fire rating of the walls in Stair B.

3M4 / 45 min

3M3 / 45 min

A2.1

200

Identify the T.O. elevator parapet.

Elevation 113 400

A4.1

200

Identify the R.O. of the windows on the East wall between GL E and GL F.

1200mm X 2200mm

A4.2

200

Identify the type and height of ceiling in Room 2:201.

WCS @ 2800mm

A3.2

200

Identify the length of the property line adjacent to Henderson Hwy.

72.573M

A1.1

300

If an interior wall does not have a wall tag, what type should it be?

4S2

A2.3

300

Provide the elevation at the high point of the crawlspace floor.

Elevation 98 500

A2.0

300

What is the R.O. size of the window along GL A.

800mm X 2800mm

A2.2, 2/A4.2

300

Identify the quantity of suspended light fixtures required for lobby 1:101.

3

A3.3

300

Identify the quantity of new light standards planned for this project.

2

A1.1

400

Identify the components for 3M3.

190 CMU

22mm furring channels

16mm gypsum board

A2.4

400

Identify the mounting height from el. 100 000 to the centre line of the exterior light fixture at door 1:106.1.

Elevation 102 500

A4.2

400

Identify the M.O. width and height of door 1:110.1.

1900mm x 2200mm

A2.1, 9/A5.3

400

Identify the quantity of return air/exhaust grilles required for the washrooms on the second floor.

5

A3.2

400

Identify the quantity of bike racks to be installed on the site.

4

1/L2.0 or Plan note 9 on A1.1

500

Identify the size of rigid insulation and steel stud size used in the parapet construction.

100mm rigid insulation

152mm steel studs

Section A5.3

500

Identify the elevation of the u/s of soffit on the North elevation.

Elevation 102 800

A4.2

500

Identify the width and height of window types W1 and W2.

W1: 800mm x 2800mm

W2: 1200mm x 2200mm

1/A4.2

500

Identify the dimension on the reveal between the wood ceiling system and the gypsum board in room 3:301.

25mm

A3.3

500

Identify the quantity of parking spots designed for this project.

41

A1.1