Evaporator Physics
Metering Devices
Troubleshooting Diagnostics
EPA 608 & Safety
System Hardware
100

This primary component acts as the "heat sponge" of the refrigeration cycle, absorbing heat into the system

  • What is the Evaporator?


100

This thermodynamic process occurs when high-pressure liquid expands across a metering restriction without heat being added or removed, keeping enthalpy constant.

What is Adiabatic Expansion?

100

Low suction pressure, high superheat, and normal/high subcooling are classic diagnostic indicators of this specific system fault.

What is a Restricted Metering Device (or Liquid Line Restriction)?

100

Under EPA Section 608, the prohibition on knowingly venting CFC and HCFC refrigerants went into effect on this exact date.

  • What is July 1, 1992?


100

This type of evaporator coil construction uses aluminum fins stacked onto copper or aluminum tubes and mechanically expanded for tight thermal contact.

What is a Tube-and-Fin Coil?

200

This type of heat load involves removing moisture from the air (dehumidification) without changing its dry-bulb temperature.

What is Latent Heat?

200

This fraction of liquid refrigerant (approx. 25% to 30%) instantly boils off across the metering restriction, cooling the remaining liquid to saturation temperature.

What is Flash Gas?

200

Turning a TXV's superheat adjustment stem in a clockwise direction produces this change in superheat.

What is an increase in superheat (starves the evaporator)?

200

This safety apparatus is mandatory for technicians whenever a catastrophic refrigerant release occurs in an enclosed space.

What is a Self-Contained Breathing Apparatus (SCBA)?

200

On suction lines $7/8''$ OD or larger, the TXV sensing bulb must be mounted at these clock positions to avoid sensing oil pools at the bottom of the pipe.

What are the 4 o'clock or 8 o'clock positions

300

As humidity and entering wet-bulb temperature rise, this happens to the dry-bulb temperature drop across an evaporator coil.

What is it decreases (temperature drop becomes smaller)?

300

The three forces acting on a Thermostatic Expansion Valve (TXV) diaphragm to maintain balance are bulb pressure, evaporator pressure, and this closing force.

What is Spring Pressure (P_spring)?

300

If a system freezes up, thaws after being shut off, and freezes up again shortly after starting, this contaminant is present in the refrigerant circuit.

What is Moisture (water freezing at the orifice)?

300

Applying an open flame torch to a copper line containing refrigerant can break the gas down into toxic hydrofluoric acid and this deadly gas.

What is Phosgene Gas?

300

This type of TXV features an internal design where high-side inlet pressure forces cancel themselves out, allowing stable operation down to 15% capacity.

What is a Balanced-Port TXV?

400

This term describes the percentage of air that passes through an evaporator coil without ever coming into contact with a tube or fin surface.

What is the Bypass Factor (BF)?

400

An externally equalized TXV is mandatory when an evaporator coil has a large pressure drop or uses this component to split refrigerant flow into multiple circuits

What is a Liquid Distributor?

400

Rapid, uncontrolled opening and closing of a TXV stem caused by an oversized valve or improper bulb sensing is known by this term.

What is Hunting?

400

Recovery cylinders must be DOT approved, gray with yellow tops, and must never be liquid filled past this percentage of their total capacity.

What is 80%?

400

Microchannel coils are built using all-aluminum structures to prevent this specific type of "ant-nest" copper corrosion.

What is Formicary Corrosion?

500

Exceeding an airflow velocity of this many feet per minute (FPM) across a wet coil causes water droplets to strip off the fins and blow into the ductwork.

What is 550 FPM?

500

On a fixed-orifice system, when outdoor ambient temperature drops, head pressure drops, causing system superheat to react in this way.

What is increase (climb/starve the coil)?

500

If a liquid line filter-drier outlet feels noticeably colder to the touch than its inlet, this condition is occurring inside the drier shell.

What is a Partial Restriction (causing premature flashing)?

500

When leak testing a system using dry nitrogen, technicians must always install a pressure regulator and this inline safety device on the nitrogen tank.

What is a Pressure Relief Valve?

500

In flooded evaporators, these zigzag baffle plates force high-velocity vapor to make sharp turns so liquid droplets fall back down before entering the suction line.

What are Eliminators (or Eliminator Baffles)?