VENTILATION
HOSE STREAMS AND APPLIANCES
BUILDING CONSTRUCTION
HAZMAT
RALEIGH FIRE POLCIES
100

THE 2 DIRECTIONS IN WHICH VENTILATION CAN BE ACHEIVED

HORIZONTAL AND VERTICAL

100

A SOLID BORE NOZZEL PROVIDES A _____ STREAM OF WATER.

SOLID

100

THE 5 TYPES OF BUILDING CONSTRUCTION

TYPE 1 - FIRE RESISTIVE

TYPE 2 - NON COMBUSTIBLE

TYPE 3 - ORDINARY

TYPE 4 - HEAVY TIMBER

TYPE 5 - WOOD FRAME

100

_______ ____ IS THE TEMPERATURE IN WHICH A LIQUID WILL CONTINUOUSLY GIVE OFF VAPORS IN SUSTAINED AMOUNTS, AND IF HELD AT THIS TEMPERTURE FOR LONG ENOUGH, WILL TURN COMPLETELY INTO GAS.

BOILING POINT

100

STRUCTURE FIRE RESPONSE

4 ENGINES

2 LADDERS 

RESCUE OR SQUAD

2 BATT CHIEFS

ISO14

200

THE 3 METHODS OF VENTILATION 

NATURAL (HOLES AND WINDOWS)

MECHANICAL (PPF AND SMOKE EJECTOR)

HYDRAULIC (FOG STREAMS)

200

A FOG NOZZLE PROVIDES A ______ STREAM

BROKEN

200

A ___ _______WALL SUPPORTS OR PARTIALLY SUPPORTS THE WEIGHT OF A BUILDING.

LOAD BEARING

200

________ _____ IS AN EXPRESSION OF FUEL/AIR MIXTURE DEFINED BY UPPER AND LOWER LIMITS.

FLAMMABLE RANGE

200

WATCH HOURS

0800-2100

300

F

T

B

C

FAR

TOP

BOTTOM

CLOSE

300

A ____ IS USED TO JOIN TWO FEMALE HOSE COUPLINGS

DOUBLE MALE

300

1. A ROOF THAT FEATURES SLOPING OR INCLINED SURFACES

2. A ROOF THAT DOES NOT FEATURE SLOPING OR INCLINED SURFACES

1. PITCHED ROOF

2. FLAT ROOF

300

_____ ___ IS THE MINUMUM TEMPERATURE A SUBSTANCE EMITS ENOUGH VAPOR TO FORM AN IGNITABLE MIXTURE BUT NOT SUSTAIN CUMBUSTION.

FLASH POINT
300

TRUE OR FALSE

AN AERIAL APPARATUS CAN BE USED TO STANDBY AT A HYDRANT OF ESTABLISH A WATER SUPPLY 

FALSE


400

THIS CUT METHOD IS PRIMARILY USED TO STOP OR SLOW FIRE PROGRESSION IN LONG, NARROW BUILDINGS SUCH AS STRIP MALLS AND STORAGE UNITS

TRENCH CUT

400

WHICH OF THE FOLLOWING HOSE SIZES CANNOT BE USED AS SUPPLY HOSE?

A. 3"

B. 2 1/2"

C. 1 3/4"

D. 4"

C. 1 3/4'

400

A CONSTRUCTION METHOD TO SUPPORT FLOORS AND ROOFS. IT CONSISTS OF SMALLER DIAMETER LUMBER JOINED TOGETHER TO FORM A STRONG, SINGLE SUPPORT MEMBER. IT IS COST EFFECTIVE COMPARED TO SOLID, HEAVY TIMBER CONSTRUCTION.

TRUSS CONSTRUCTION

400

A MATERIAL WITH A PH VALUE GREATER THAN 7

BASE

400

PERSONAL FLOATATION DEVICE SHALL BE WORN WITHIN __ ___ OF THE WATER EDGE

10 FEET

500

THIS CONDITION OCCURS WHEN THERE IS A SIGNIFICANT TEMPERATURE DIFFERENCE BETWEEN OUTSIDE AIR AND THE AIR INSIDE A BUILDING (TYPICALLY HIGH RISE BUILDINGS) DURING AN ACTIVE FIRE. 

EXAMPLE - THE FIRE IS ON THE TOP FLOOR BUT SMOKE CONDITIONS ARE WORSE ON THE GROUND FLOOR.

STACK EFFECT 

WINTER AND SUMMER

500

NOZZLE OPERATING PRESSURES (IN PSI)

1. SMOOTH BORE HANDLINE ____

2. LOW PRESSURE FOG ____

3. SMOOTH BORE MASTER STREAM _____

4. STANDARD FOG _____

1. 50 PSI

2. 50 PSI

3. 80 PSI

4. 100 PSI

500

A _______ ___ IS BEST DESCRIBED AS A SECTION OF WALL THAT APPEARES TO BE LOAD BEARING BUT IS ACTUALLY NOT AND IS STRICTLY FOR ASTHETICS ONLY. THESE WALLS ARE TYPICALLY BRICK AND/OR LAYERD STONE.

VENEER WALL

500

THE WEIGHT OF AN AIRBORN CONCENTRATION (VAPOR OR GAS) COMPARED TO WEIGHT OF AIR.

VAPOR DENSITY

500

IF OXYGEN CONCENTRATIONS IN A SPACE DROP BELOW ____ MEMBERS SHALL WEAR SCBA

19.5%