Trouble shooting
Error codes
Furnace 101
Components for a Gas Furnace
Miscellaneous
100

When voltage is read across a fuse, this indicates the fuse is...?

Blown

100

When receiving a flame verification code, what should the issue be?

Dirty flame sensor

100

What does BTU stand for?

British thermal unit

100

What is the IDF

Induced Draft Fan

100

What can cause a motor to over amp

Low cap range or bearings wearing down causing friction

200

When 24v error code is presented, what does this mean?

There is no 24v power after the fuse

200

When a system over heats three times consecutively, what error code will be presented?

Limit circuit lockout

200

For a 4 ton system, how many CFM is required?

1600 CFM

200

What is a TRAN

Transformer

200

Whys is a bypass humidifier worse than a fan powered?

Bypasses steal air from the system and re-circulate heat

300

When testing for a bad wire, what are you searching for on your meter?

Continuity 

300

When given an ignition lockout error code, what has happened?

System failed to prove flame was present, so the furnace went into a 3 hour lockout

300

What can cause the breaker to pop when a furnace turns on?

Direct short to ground 

300

A stack switch is what kind of switch?

Limit switch

300

This wire is mandatory for a thermostat that is powered by furnace?

Common wire

400

What is the main cause of a limit switch lockout?

Air flow

400

On a Carrier furnace, what does rapid LED flashing mean?

Line voltage polarity is reversed

400
Why is it important to leave blower door in when measuring temp split?

To measure with a sealed system so reading as accurate

400

What is an ILK

Blower door interlock switch

400

How often should ducts be cleaned?

Every 5-10 years

500

Why is it important to inspect venting on a pressure switch error?

If venting is too close together it can cause air circulation issues, and if there is a dip in the venting it can cause water build up which restricts air flow out the exhaust 

500

When receiving a pressure switch code for a 90% furnace, what four things should you check?

Inducer function

Pressure switch function

Condensate trap/Drain line

Venting

500

What is the sequence of operations for a furnace

Thermostat calls for heat, control board does safety check, IDF turns on, pressure switch closes, igniter turns on, gas valve opens, furnace lights, flame sensor proves flame, 30-60 second blower delay, thermostat satisfies 

500

What is a GVR?

Gas valve relay

500

How does a modulating gas valve work?

Modulates gas pressure size based off negative pressure through collector box