Framing
Blueprints
Safety
Plumbing
Electrical
Misc.
100

Framing member above a door or window

What is a header

100

the ability to read line, symbols, dimensions, notes, and other information on the print or plan.  

What is interpretation

100

The most deadly of OSHA's fatal four

What is Slip Trip Fall

100

DWV is short for

Drain, Waste, Vent

100

Most common residential wire gauge, breaker size, and sheathing color

14 gauge, 15 amp breaker, white

100

Typical blueprint scale

What is 1/4" = 1'

200

48" On Center

is not a common stud framing layout
200

A schedule lists this

What are door and window sizes

200

This is how much of a hardhat can be covered by stickers or other labels

What is 40%

200

Commonly used for Drain, Waste, Vent

What is PVC

200

A three way switch controls lights from how many locations

2 locations
200

Width of the saw blade is known as

What is the kerf

300

How far from each edge should a wire pass through a stud? 

What is 1 1/4"

300

A cutaway view used to show interior, complex, or hard to see details

What is section view

300

OSHA Stands for

Occupational Health and Safety Administration

300

Faucets must be designed to prevent

What is Backflow

300

A short wire twisted to others used to isolate an outlet from a circuit  

What is a pigtail?

300

CPVC stands for

Chlorinated Polyvinyl Chloride

400

Rough openings must either be larger or the same size as the window opening, which is true? 

What is rough openings must be larger
400

The dimensional relationship of the full sized structure to the drawing is based upon

What is scale

400

Z87

Properly certified safety glasses

400

This component prevents sewer gases from coming up through the drain

What is a P-Trap

400

What colors are the three terminals on a single pole switch

2 gold/brass, 1 green

400

NM Stands for

Non metallic sheathing

500

Partial vertical studs that fall on layout

What are cripple studs
500

These are the three basic views used in construction prints

What is Plan, Section, Elevation

500

Daily inspection of an excavation must be performed by a(n) _____

Competent Person

500

Water flow is routed from a tub spout to a shower head by activating 

What is the diverter valve

500
#12 gauge wire goes with what size breaker

What is 20 amp breaker

500

A cut list calls for a stud length of 92⅝ inches for an 8′ wall.

Why is this shorter than 96 inches?

What is to allow for the thickness of the bottom plate and double top plate?

1000
Name all 7 components of a wall with a window
Stud, bottom plate, top plate, jack stud, king stud, cripple, header.
1000

A floor plan is drawn at ¼″ = 1′-0″.
A wall measures 3½ inches on the blueprint.

What is the actual length of the wall in feet?

14 feet

1000

A ladder is set on a jobsite at a 4:1 ratio and extends 3 feet above the landing, and is placed directly in front of an unlocked doorway.

What is the primary safety violation?

The ladder being placed in front of a doorway without blocking the door

1000

When measuring for an accurate pipe length, the ___________________ should be
considered before cutting.

Overlap of the pipe and fitting

1000

On a standard three prong plug, the wider flat blade is connected to

White or neutral

1000

A contractor is tiling a backsplash that is 20' by 18". How many tiles are required if each tile is .25 sq ft each, and accounting for 10% overage

18 / 12 = 1.5

1.5 x 20 = 30

30 / .25 = 120

120 x .1 = 12

120 + 12 = 132


132 Tiles