Trudging towards Climate Goals
Energy and Heat
Air & Moisture
Building Design
Electrical Efficiency
100

Apart from CO2, what's one example of a Greenhouse Gas (GHG)? 

  • Methane CH₄- (Sources: Agriculture (livestock, rice paddies), landfills, fossil fuel extraction.)

  • Nitrous oxide -N₂O (Sources: Agricultural fertilizers, burning biomass, some industrial processes.)

  • Fluorinated gases- Human-made chemicals (eg HFCs, PFCs, SF₆, NF₃) used in refrigeration, air conditioning, electronics. Very potent. 

  • Water vapor -H₂O (Most abundant natural greenhouse gas. Not directly controlled by humans, but influenced by warming (feedback loop: warmer air holds more moisture)

  • Ozone O₃ (Exists naturally in the stratosphere. Good ozone = UV shield. It’s a pollutant and greenhouse gas.)

100

Energy equals power multiplied by this.

Time

100

Cold air entering low and warm air escaping high is this effect

Stack effect

100

“16 OC” framing, OC stands for this.

on center

100

Upgrading to this fixture type is the first lighting-efficiency strategy.

LED Lighting

200

Beyond ___°C of warming, scientists warn of chains of events beyond human control.

1.5°C

200

Sitting next to a fireplace, you mostly feel this type of heat transfer, which needs no medium 

Radiation

200

When moisture travels as liquid it is called?

Bulk transport

200

What's the difference between a "stud" and a "rafter"

A rafter is a sloped framing member that supports the roof, while a stud is a vertical member that supports an interior/ exterior wall

200

What are occupancy (or vacancy) sensors?

Devices that switch lights off when no one is in the room

300

WAP is an acronym for a federal program supporting the upkeep and workforce for energy efficient buildings. What does WAP stand for?

Weatherization Assistance Program

300

This type of heat causes a substance to change phase.

Latent Heat

300

Water spreading through a half-wet paper towel is an example of this moisture movement.

Capillary action

300

What does a thermal boundary of a building differentiate between?

Conditioned and unconditioned spaces
(which we know the definitions for)

300

3 Low/No-Cost actions building occupants can take for more efficient electricity use

Unplug unused equipment

Use task lighting

Smart power strips

Calibrate sensors

Extend thermostat deadbands (allow indoor temperature to drift over a larger range before heating/ cooling turns on)

400

Scientists tell us we are currently living in the 6th Mass Extinction, known as the Anthropocene. What are defining features of the Anthropocene?

  • Caused by human activity such as farming, hunting, fishing, logging/deforestation, mining, burning, dumping, spilling, venting, wasting, 

  • Results of human activity: Climate Change, Hole in the Ozone layer, Air Pollution, Water Pollution, human suffering…

  • The Industrial Revolution and the burning of fossil fuels is responsible for today’s carbon levels

400

A cup of coffee cooling to room temperature illustrates this law of thermodynamics.

The second law

energy will always move from higher concentration to lower concentration; never in reverse unless energy is added to the system from outside of it

400

What is vapor diffusion?

When moisture in the form of a gas travels through a solid, porous materials due to differences in pressure

400

Where will i find a jack stud?

Beside a window opening and carrying a header

400

What is peak shaving?

Using stored battery energy to cut demand during high-use periods is called this

500

To the quiestest person in the group: In your own words, what is sustainability?

~ A way of living that meets the needs of today without preventing future generations from meeting their own needs.

500

Two 1,000-watt electric heaters running for 2 hours produce about this many BTUs.

About 20,470 BTUs

1kwh of electricity = 3412 BTU’s of heat produced at the site where it is being used.  So a 1000 watt (1kwh) electric heater will produce 3412 BTUs of heat in 1 hour.  If you had 3 of these heaters working together, 3412BTUs/KWH*3Hours*2Heaters= ___

500

In thinking about air movement throughout a building, a mechanical effect can lead to discomfort, wasted energy, and possibly dangerous indoor conditions; Explain what the mechanical effect is.

An imbalance in the ventilation system, leading to over exhaust and under return. If buildings aren’t provided enough “return” air, also called makeup air, they will become imbalanced and fall under a negative pressure.

500

What is the Heating Degree Day (HDD) for a day when the high was 27 and the low as 13?

45 

It is calculated by subtracting the average outside temp from 65 degrees. Add the high and the low for the day. Divide by 2 (or number of days) then subtract the average from 65.

500

What does NEC stand for?

National Electrical Code