Fire Water Ring
Fire Truck
SCBA
H2S
Gas Testing
100

We have two of these and their job is to maintain system pressure of 100 psi

What are Jockey Pumps

100

I am carried on the Fire Truck to help combat hydrocarbon fires when mixed with water

What is Firefighting Foam

100

SCBA stands for

What is Self-Contained Breathing Apparatus

100

10 PPM

What is the PEL- Permissible Exposure Limit

100

I am used mainly for confined space entry and I can detect Oxygen content, Lower Explosive Limit, and Hydrogen Sulfide

What is BW Micro 5 Gas Monitor

200

At 70 PSI I start to meet required fire flow during an emergency

What is the Electric Fire Pump

200

I am orange and mounted around the exterior of the Fire Truck to monitor 2 gases

What are H2S and SO2 detectors

200

I contain approximately 9L of air and can last up to 60 minutes

What is an SCBA Cylinder

200

15 PPM

What is the STEL- Short Term Exposure Limit

200

I occur when the oxygen level is below 19.5 %

What is Oxygen Deficiency

300

I start if there is a system pressure drop to 60 psi

What is the Diesel Fire Pump

300

There are 6000 liters of me carried on the Fire Truck

What is foam

300

My job is to activate when a firefighter is either unconscious, trapped, lost, or disoriented

What is a PASS Device

300

When exposed to 100-200PPM I am paralyzed and a person can no longer smell H2S

What is the Olfactory Nerve

300

I activate when 5% of LEL, less than 19.5 or greater than 22.5% O2, or 10PPM H2S is reached

What is the audible alarm

400

I am the only Fire Pump that shuts off automatically when I reach a desired pressure

What are Jockey Pumps

400

I can flow up to 10,000 LPM if I have adequate water supply

What is the roof monitor

400

I activate when my air supply is down to approximately 1/4 full

What is the Audi-Alarm

400

At 4.3% or 43,000 PPM the fuel and air mixture is perfect for me to burn

What is the LEL

400

I am produced when H2S is burned and a bright blue flame is noticed

SO2- Sulfur Dioxide

500

There are 22 of me in the CDS. 14 in Train # 2 and 8 more around the FST area

What are fully automatic monitors

500

I am located on the rear of the Fire Truck and there are 5 of me. (4) 2 1/2" and (1) 4 1/2"

What are discharge valves

500

Physical condition of the wearer, level of training, environmental conditions, emotional stress, job or task being performed, amount of air in the cylinder

What are limitations of SCBA

500

My ____ ______ is greater than 1 so I will seek out low lying areas

What is Vapor Density

500

I am the lag time required when using a BW Micro-5 Gas Monitor with extendible hose to ensure an accurate reading

What is 3 seconds per foot of tubing