100

the principal reason for image integration is to ______? 

improve contrast resolution

100

a conventional radiograph is which of the following? 

an analog image

100

during digital fluoroscopy, the_______? 

the x-ray beam is pulsed

100

the combination of temporal subtraction and energy subtraction techniques is called_______? 

hybrid subtraction

100

an advantage of digital imaging over conventional imaging is which of the following? 

postprocessing

200

the maximum frame acquisition rate in digital fluoroscopy is about______? 

30 frames per second

200

which of the following components found in digital fluoroscopy is not found in conventional fluoroscopy? 

an analog-to-digital converter (ADC). 

200

digital fluoroscopy is conducted in________? 

in the progressive TV mode.

200

the minimum acceptable TV signal-to-noise ratio for digital fluoroscopy is________? 

1000:1

200

a pixel is a _______? 

two-dimensional digital image cell

300

the signal-to-noise ratio of a conventional TV camera tube is about______? 

200:1

300

during digital fluoroscopy, the image receptor is which of the following? 

the image-intensifier tube

300

how many video monitors are required for digital fluoroscopy? 

2

300

interrogation time is_______? 

is the time needed to switch on the x-ray tube

300

between the TV camera and the computer of a digital fluoroscopic system is a/an_______? 

analog-to-digital converter. 

400

compared with conventional fluoroscopy, digital fluoroscopy is conducted at________? 

at much higher x-ray tube current

400

a principal advantage of digital fluoroscopy over conventional fluoroscopy for subtraction studies is_____? 

contrast enhancement

400

the time-interval difference mode is best used for which of the following? 

dynamic studies

400

a digital imaging system with a dynamic range of 210  will be able to reproduce how many shades of gray? 

1024 shades of gray

400

the mask image is usually the_________? 

first image

500

digital imaging systems can display images on a 1024 x 1024 matrix. how many pixels are present in such matrix? 

1,048,576

500

the approximate pixel size for a 12-inch image intensifier tube and a 256-reconstruction matrix is______? 

1.0 mm

500

reregistration of an image is used to do which of the following? 

correct for motion 

500

an advantage of temporal subtraction over energy subtraction angiography is________? 

higher contrast at lower dose

500

energy subtraction is based on which of the following? 

K-edge absorption