Duct Work
Electrical
Random HVAC Questions
Condensate/Electrical
Installation
100

Ductboard duct sections are fabricated from which material?

  • Fiberglass
100

The applied voltage (the voltage that the unit will actually be using) should be within ±_____% of the rated voltage of the unit.


10 +/-

100

On a new package system, the refrigerant charge is


added to the system at the factory

100

A float switch, located in an auxiliary drain pan, is typically wired to


open the low-voltage control circuit.

100

When installing the condensing unit of a split-system, it should be


set on a concrete or high-impact plastic pad.

200

Square duct or rectangular duct is assembled with


“S” fasteners and drive clips.

200

The standard wire size for light-duty low-voltage wire is


18 gauge.

200

When sizing and selecting air conditioning equipment, which of the following must be taken into account?


Moisture content

200

The condensing unit of a split-type air conditioning system is made up of the 


condenser coil and compressor.

200

On a line set used to install a split-system, the ______ line is insulated.


suction

300

To help create an airtight seal between duct sections


mastic may be applied

300

The __________ provides installation standards, wire sizes, methods of routing wires, and types of enclosures for wiring and disconnects.


National Electrical Code (NEC)

300

Package-type air conditioning units are intended to be located


either on the roof of a structure or at ground level.

300

When measuring voltage across an open safety switch (like a tripped high-limit switch) while the system is calling for heat, what voltage should you read?

24V AC. (Because the switch is open, you are measuring the potential difference across the break in the line).

300

The condenser of a split-system typically contains enough refrigerant for ____ ft of line set.


25

400

When joining two sections of fiberglass ductboard


staples and tape are used.

400

In a standard single-stage heating and cooling system, which terminal controls the indoor blower fan, and what color wire is typically used?

G terminal, typically using a Green wire.

400

What refrigerant lines are field installed on the typical package-type air conditioning unit?


Package-type equipment has no field-installed refrigerant lines.

400

What is the industry-standard color and terminal designation for the continuous 24V power supply from the transformer?

Red (R).

400

After installing the refrigerant lines on a split-system, the next step would be to


pressurize the system with nitrogen for a leak test.

500

A typical multihead, ductless split system is configured with 


multiple indoor units and one outdoor unit.

500

What is the difference between the O and B terminals on a heat pump thermostat?

Both control the reversing valve. O energizes the reversing valve in cooling mode. B energizes the reversing valve in heating mode.

500

The two types of heat transfer that are facilitated by the evaporator are


sensible heat and latent heat.

500

Question 3: What is the purpose of the "C" terminal, and why is it required for modern smart thermostats?

The Common (C) wire completes the 24V AC circuit, providing continuous power to the thermostat's internal electronics without relying on batteries or power-stealing.

500

Line sets typically come in standard lengths of


25 and 50 ft.