INSTALL
WASTE
VENT
WATER
GAS
100

WHAT ARE THE 4 MAIN TYPES OF COPPER TUBING?

TYPE K, TYPE L, TYPE M, DWV
100

WHAT ARE THE TWO MAIN SLOPES ALLOWED ON A SEWER LINE?

1/4" PER FOOT AND 1/8" PER FOOT

100

CAN A VENT LINE BE FLAT?

YES

100

HOW DO YOU CLEAN A WATER SYSTEM?

CLORINATE THE SYSTEM

100

DOES NATURAL GAS HAVE A SMELL?

NO, THE GAS COMPANY ADDS AN ODOR TO THE GAS

200

WHAT DO YOU LOOK AT FOR THE CORRECT ROUGH IN DIMENSIONS?

THE MANUFACTURERS CUT SHEETS

200

HOW MUCH DROP DO YOU HAVE IN ELEVATION FOR A 76' RUN OF 2" DWV PVC?

19" OR 1'7"

200

ARE YOU ALLOWED TO TIE TWO VENTS TOGETHER UNDERGROUND?

NO

200

CAN YOU RUN A HOT WATER SYSTEM IN PVC SCH.40?

YOU CAN NOT

200

WHAT IS BTU?

BRITISH THERMAL UNIT

the amount of heat needed to raise one pound of water at sea level by one degree Fahrenheit

300

WHAT IS THE ADA DIMENSIONS FOR A WATER CLOSET FROM THE SIDE WALL AND HEIGHT?

SIDE WALL=17"-18"

HEIGHT=17"-19"

300

WHAT IS THE SMALLEST DRAIN LINE FOR A GRAVITY TOILET?

3"

300

WHAT SIZE VENT NEEDS TO LEAVE THE BUILDING?

SAME SIZE AS THE SEWER LEAVING THE BUILDING

300

WHAT IS THE MAIN REASON FOR A HOT WATER RETURN SYSTEM?

TO KEEP THE WATER IN THE PIPES NEAR THE POINT OF USE HOT

300

WHAT IS CFH?

CUBIC FEET PER HOUR

a unit of measurement to quantify the volumetric flow rate of gas

400

WHEN IS THE TIME TO INSTALL A POLYETHYLENE GAS LINE INSIDE THE BUILDING?

NEVER, THIS PIPE IS ONLY ALOWED OUTSIDE UNDERGROUND

400

HOW MANY WATER CLOSETS CAN BE INSTALLED ON A 3" MAIN LINE?

6 WATER CLOSETS

400

WHAT HEIGHT ABOVE A FLOOD LEVEL CAN YOU TIE MULTIPLE VENTS TOGETHER?

6" ABOVE

400

WHAT IS THE SIZE OF WATER NEEDED FOR A FLUSHVALVE ON A URINAL?

3/4" WATER

400

WHAT IS THE TESTING PRESSURE FOR POLYETHYLENE?

60 PSI

500

WHEN MUST YOU INSTALL A SEWAGE EJECTION SYSTEM?

WHEN THE SEWER POC IS ABOVE THE BUILDING SEWER INVERT

500

WHY WOULD YOU NEED A BACKWATER VALVE PER THE CITY?

YOUR LOWEST DRAINS IN THE BUILDING ARE LOWER THAN THE NEXT CITY MANHOLE

500

WHAT IS THE MINIMUM SIZE VENT YOU CAN HAVE ON A WATER CLOSET?

2"

500

HOW MUCH PSI DO YOU GAIN OR LOOSE ON ELEVATION CHANGE?

1/2 PSI + -

500

WHAT IS THE MAXIMUM PRESSURE FOR A MEDIUM PRESSURE GAS SYSTEM?

5 PSI