HFC NETWORK
CABLING
FREQUENCY
ATTENUATION
TOOLS
100

Field Techs are responsible for this part of the HFC Network

What is the Tap to the CPE

100

How many inches of sag should an aerial drop have per 50 feet?

What is 6 inches

100

A signal making 1 alternating cycle per second would have a frequency of:

What is 1 Hertz

100

The 5 factors of attenuation are:

What is Temperature, Distance, Cable Type, Dielectric & Frequency
100

This tool is used to determine length, locate faults & passives on the line

What is Time Domain Reflectometer (TDR)

200

This component of the HFC Network is where the fiber optic signal is converted to an electric signal that travels through coax

What is the Node

200

This type of cable is not carried by Charter, we only carry the fittings

What is RG-59

200

1 mV measured across 75 ohms is equal to:

What is 0 dBmV

200

Your upstream reading at the output of a balanced 3-way splitter is 49.5 dBmV. What is it at the input?

What is 44 dBmV

200

This tool can help identify which interior wire is going to which room

What is Toner & Probe

300

This is where the CMTS is located

What is the Headend
300

This is the minimum distance a span clamp should be installed from a tap

What is 6"

300

This is Charter's upstream frequency range

What is 5-42 mHz

300

This unit of measurement reflects signal loss/gain

What is dB

300

This tool is used on CLI jobs

What is Leakage Detector (dipole/field probe/HL Seeker)

400

This borough in NYC is where the S hub is located

What is Brooklyn

400

If cables and power lines run parallel, keep them a minimum of ___ inches apart and if they intersect, keep them at ___ degree angles

What is 12 and 90
400

The number of alternating cycles per second a signal is making at 550 mHz is:

What is 550 million

400

57 mHz shows a reading of -7 dBmV at the output of a 2 way splitter. What is it at the input?

What is -3.5 dBmV

400

This tool can be useful for accessing NIDs and tightening span clamps

What is Can Wrench

500

This is an active device which decreases attenuation within the plant

What is an Amplifier

500

To protect drop cable when it enters and exits the ground, the conduit must go at least ___ inches into the ground with an ____ inch deep hole to accommodate the proper bend radius.

What is 3 and 8

500

The LTE 4G frequency band is:

What is 698-806 mHz

500

This is the loss of the passive leg on an Integrated Signal Amplifier

What is 3.5 dB

500

To test for ingress on downstream frequencies using my Viavi meter, I would go to ChannelCheck and scroll down to

What is IUC/Ingress Under Carrier