CATEGORY 1
CATEGORY 2
CATEGORY 3
CATEGORY 4
CATEGORY 5
100

Nomenclature for CBL

What is Containerized Batch Laundry

100

Water source that is used for all 3 92S systems

What is the 3K gallon collapsible tank

100

The 3 items that are inserted into the auto soap dispenser

What is laundry detergent, bleach, and laundry sour

100

The amount of laundry a CBL can process per hour

What is 150-200 pounds?

100

This is used for easy entry in and out of the CBL for carts to move more effectively.

What is the ramp?

200

This is used to filter impurities and biotoxins from the reuse system

What is nano-filtration system?

200

This is the size of the Type XII TEMPER tent

What is 16'X20'?

200
This must be done before starting any cycle.

What is initial fill?

200

Distributes power throughout the CBL with the exception of the dryers

What is the main electrical panel?

200

The weight of the loads of laundry that the washer can process

What is 50 pounds?

300

This panel controls automated operations to both washer and dryers within the CBL

What is programmable logic control

300

The amount of grey water the CBL recycles

What is 50%?

300

This collects the filtered and purified water that will be recycled through the washers during a subsequent wash cycle.

What is the reuse tank?

300

The longest laundry cycle

What is nanofilter storage (sodium bisulfite)? 85:00

300

This is used in the event of an emergency to shut down all systems within the CBL

What is the emergency shutdown switch?

400

These mos's directly support maintenance for quartermaster equipment.

What is 91J & 91D?

400

This side of the CBL runs off of 100 amp power

What is the dryer side?

400

The CBL can receive 208V, 3 phase, 60 Hz, power from these two power sources

What is 100 KW generator or municipal power?

400

The washer recycle thank should be maintained at this temperature approximately.

What is approximately 110 degrees.

400

The 3 utility connections of the CBL

What is fresh water, grey water, and electrical power?

500

These are used as verification that electrical power is connected correctly and that everything is in proper sequence before operation.

What are phase indicator lights?

500

The technical manual for the Containerized Batch Laundry

What is TM 10-3510-226-10?
500

This is the total amount of phase indicators that shows proper phasing for washers and dryers

What are 3 phase indicators.  (1 washer, 2 dryer)

500

These are used for temperature control and ventilation

What is FDECU & ASH?

(Army Space Heater: used to heat the TEMPER & CBL during cold weather operation

FDECU: installed outside of the TEMPER and controls temperature inside of the TEMPER & CBL)

500

These vents need to be open when utilizing the F-1B valve

What is F-1B, F-2, F-3, and F-4?