FIRE HOSE
VALVES & APPLIANCES
HYDRANTS
FIRE ATTACK
HOSE CARE & STORING
100

Fire hose that transport water from a fire hydrant or other water supply source to an apparatus equipped with a pump

What is supply hose

100

The type of valve applied to hydrants to control the flow. 

What is Gate Valve. 

100

The hydrants in the PNW are these types of hydrants. 

What is Dry-Barrel Hydrants

100

This nozzel has a straight, smooth tip and produces a solid stream of water

What is smooth bore nozzel

100

This hose roll allows the firefighter to control both of the couplings. 

What is donut roll. 

200

The traditional length of fire hose sections in North American. 

What is 50 ft. 

200
Appliance to divide a single hoseline into two of more lines. 

What is Wye Appliance. 

200

Fire hydrants (and nozzels) must be opened and closed slowly to prevent this and cause damage to the equipment. 

What is water hammer. 

200

Before advancing a hose line into a structure, a firefighter should always open the nozzel fully to check this. 

What is adequate water flow or pressure. 

200

On a female coupling, two things should always be check before making the connection. Name one of them. 

What is gasket present and plyable OR swivel moves. 

300

The name of the wrench used to tighten fire hose connections/couplings

What is spanner wrench. 
300

Appliance to combine multiple lines into one line. 

What is Siamese appliance 

300

The large outlet for large diameter supply hose on the hydrant is called this. 

What is steamer connection or pumper outlet.

300

This stream can be used for hydraulic ventilation or firefighter protection. 

What is fog stream. 

300

This hose load can be carried on the shoulder, completely clear of the ground, which makes it less likely that the hose will catch on obstacles. 

What is Minuteman load. 

400

Most common coupling on large diameter hose. 

What is Storz. 

400

The type of valve used in a Siamese appliance to allow water to only flow in one direction. 

What is Clapper valve. 

400

The hydrant wrench is attached to this to open and close the hydrant. 

What is stem nut. 

400

When the fire is to large for handlines, or hose streams are needed in areas unsafe for firefighters, you would use this device. 

What is Master stream device OR ground monitor. 

400

How often fire hose be service tested

What is annually. Yearly. 

500

The name of th eindicator on a male and female couple to prevent cross-threading. 

What is Higbee cut

500

A fitting that would be used to connect two male couples of the same diameter. 

What is double-female

500

What size are the two smaller outlets on a hydrant or the only outlets on a "village hydrant"

What is 2.5 inches 

500

In addition to a dump site at the fire and a fill site at the water source, this is needed for a water shuttle operation. 

What is mobile water supply apparatus to haul the water (Tenders)

500

This type of damage can occur to natural fiber hose, when it is stored wet, putting it at risk of mold and mildew. 

What is organic damage.